NBR 6118 doesn't hand a raft foundation its own dedicated chapter — this module reaches it the same way as every other NBR-coded plate-type member in this series, running the rigid-method strip analysis through the code's general flexure and shear provisions rather than a raft-specific clause.

Every check above runs automatically inside the Structyze Raft Foundation module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Raft foundation, overall plan 8.0 × 6.0 m, depth 600 mm (d = 540 mm)
  • Total factored column load Nd = 5400 kN across 6 columns
  • Critical design strip moment Md = 265 kN·m per metre width
  • Concrete C25 (fcd = 17.86 MPa); reinforcement CA-50 (fyd = 434.8 MPa)

Working Through It

The rigid method treats the raft as a set of independent design strips between column lines, each checked exactly like a continuous beam. On the governing 1 m strip, required steel at Md = 265 kN·m works out to As ≈ 1270 mm²/m, with x/d ≈ 0.158 — comfortably inside Domain 3.

Punching shear is still checked per column specifically as an isolated footing would be, using NBR 6118's own αv2 = (1−fck/250) reduction on the concrete-crushing term VRd2; the heaviest-loaded interior column reaches utilisation 0.68 against this limit.

What Governs, and Why

Flexure on the governing design strip reaches utilisation 0.83, ahead of the heaviest column's punching check at 0.68 — a typical pattern for a rigid-method raft sized on a reasonably uniform soil-bearing assumption rather than by any single concentrated load.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Raft Foundation module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Raft Foundation and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why doesn't NBR 6118 have a dedicated raft-foundation clause?

NBR 6118 is written as a general concrete-structures code, not a geotechnical-foundations one — it supplies the flexure, shear and punching provisions any plate-type member needs, and the rigid-method strip idealization that turns a raft into a set of checkable beams is foundation-engineering practice layered on top, the same approach IS 456 and ACI 318 both take in this series' equivalent raft posts.

What does αv2 actually do in the punching check?

It reduces the concrete's crushing resistance as strength class rises, reflecting that very high-strength concrete becomes progressively more brittle rather than gaining crushing capacity in direct proportion to fck — a genuine NBR 6118 refinement that most other codes in this series fold into a flatter, less strength-sensitive coefficient.

Final Thoughts

A rigid-method raft under NBR 6118 leans on the same strip-idealization shortcut every code in this series uses — the real code-specific content shows up in the punching-shear reduction factor, not in how the raft itself gets broken into strips.

Leave a Reply