GB 50010's punching-shear check for an isolated footing sets its critical perimeter at h0/2 from the column face — numerically the same setback ACI 318 uses. But pairs it with a flat 0.7ft concrete term instead of ACI's three-way minimum of b0, βc and αs expressions.

Every check above runs automatically inside the Structyze Isolated Footing module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The Example We'll Use

  • Square footing 2.4 × 2.4 m, depth 500 mm, h0 = 450 mm
  • Column 400 × 400 mm, factored axial load Nu = 1600 kN
  • Net upward soil pressure (factored) pu ≈ 278 kPa
  • Concrete C30 (ft = 1.43 MPa); reinforcement HRB400 both ways

Working Through It

Critical perimeter at h0/2 = 225 mm from the column face gives a punching perimeter of 4×(400+450) = 3400 mm. Punching capacity: Vu,p = 0.7×1.43×3400×450 ≈ 1,531.5 kN against a net punching force ≈ 1,399.2 kN — utilisation 0.914, the tightest check on this footing.

One-way (beam) shear at a section h0 from the column face checks Vu,c = 0.7×1.43×2400×450 ≈ 1,081.1 kN against a demand well under half that, and flexural steel at the critical section comfortably exceeds the 0.2% minimum ratio floor — both secondary to punching.

What Governs, and Why

Punching shear governs at utilisation 0.914, leaving real but not generous margin — a direct consequence of GB 50010's flat 0.7ft term carrying less reserve here than ACI 318's βc-and-αs-adjusted expressions would for this exact column aspect ratio and location.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Isolated Footing module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The free trial covers a curated set of flagship modules including this one. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does GB 50010 use a flat 0.7ft term instead of ACI's three-part minimum?

GB 50010 doesn't separately credit column aspect ratio (βc) or interior-versus-edge column location (αs) the way ACI 318 does — it applies one tensile-strength-based term uniformly, simpler to apply but giving up some of the extra capacity ACI would credit a square interior column like this one.

Is a 0.914 utilisation on punching shear too tight in practice?

It's a legitimate pass with little spare margin for load underestimation or construction tolerance — increasing footing depth by even 50–75 mm would move this comfortably lower, a cheap way to add real robustness on a check this close to 1.0.

Final Thoughts

A GB 50010 punching check reaching 0.914 is a useful reminder that the code's simpler, flatter formula doesn't automatically mean less restrictive — it can land tighter than a more detailed ACI-style breakdown would for the same geometry.