NBR 6118 classifies every flexural section by which strain 'domain' it falls into — domain 2, 3 or 4, based on whether the concrete or the steel reaches its limiting strain first — vocabulary genuinely distinct from Eurocode 2's own under-reinforced/over-reinforced split, even though both codes chase the identical ductility goal.

Every check above runs automatically inside the Structyze Combined Footing module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Combined footing supporting two columns, overall length 4.5 m, width 1.8 m, depth 600 mm (d = 540 mm)
  • Factored moment at the critical section Md = 410 kN·m
  • Concrete C25 (fck = 25 MPa, γc = 1.4, fcd = 17.86 MPa)
  • Reinforcement CA-50 (fyk = 500 MPa, γs = 1.15, fyd = 434.8 MPa)

Working Through It

With λ = 0.8 and NBR 6118's 0.85 sustained-load factor on fcd, the design compressive resistance is 0.85×17.86 ≈ 15.18 MPa. Solving for required reinforcement at Md = 410 kN·m on a 1800 mm width gives As ≈ 2075 mm², with a resulting neutral-axis ratio x/d ≈ 0.207.

That x/d of 0.207 sits inside NBR 6118's Domain 3 — concrete reaches its 3.5‰ limiting strain just as the steel yields, the code's own target ductile-failure zone, confirming the section isn't over-reinforced.

What Governs, and Why

The section lands cleanly in Domain 3 at utilisation 0.91 against the governing moment — NBR 6118's minimum-reinforcement table (ωmin, tabulated by concrete grade rather than Eurocode 2's fctm-based formula) is checked separately and found non-governing, since the flexural steel already well exceeds the table's minimum ratio for C25 concrete.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Combined Footing module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Combined Footing and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

What distinguishes NBR 6118's domains from Eurocode 2's under/over-reinforced split?

Both describe the same underlying mechanics, but NBR 6118 names four distinct strain-distribution zones across the section — pure tension, under-reinforced flexure, balanced-ish flexure, and compression-dominated — as a formal classification engineers identify by number, where Eurocode 2 just checks x/d against a single threshold without naming the zone.

Why does NBR 6118 use a tabulated ωmin instead of Eurocode 2's formula?

NBR 6118's calibration for minimum reinforcement is presented as a lookup table keyed directly to concrete strength class, a format the code favors in several places over a continuous formula — both approaches target the same crack-control intent, but NBR 6118's version doesn't need fctm computed as an intermediate step.

Final Thoughts

Learning to read NBR 6118's domain language pays off well beyond this one footing — it's the same four-zone vocabulary the code uses to classify every flexural member in this series' Brazilian-code posts.

Leave a Reply

Your email address will not be published. Required fields are marked *