AS 4100's member section constant αb genuinely goes negative for a cold-formed hollow section — not a typo, but a real, disclosed feature reflecting that cold-forming's own residual-stress pattern happens to be more favourable to buckling resistance than a hot-rolled open section's.

Every check above runs automatically inside the Structyze Compression/Tension Member module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Section 250 × 250 × 12 × 8 mm (I-shape/channel)
  • Effective length 3.5 m
  • Section/fabrication category: hot-rolled open section, αb = 0
  • Axial: dead 200 kN, live 150 kN (pure axial)
  • Material AS/NZS 3679.1 Grade 300, fy = 300 MPa

Working Through It

The governing factored load compares two combinations: 1.35G alone (272.8 kN) against 1.2G+1.5Q (467.5 kN) — the live-load-inclusive combination governs, as it typically does once live load is a meaningful fraction of the total.

The buckling chain: modified slenderness λn = (le/ry)√(fy/250) = 60.58, then αa = 20.63 from a slenderness-dependent formula, λsl = λn + αaαb = 60.58 specifically (since αb = 0 for this hot-rolled section), and finally αc = 0.805.

φNc = 0.9(0.805)(2342.4) ≈ 1697.4 kN against the 467.5 kN demand.

What Governs, and Why

Compression buckling governs at utilisation 0.275, tracking closely with the slenderness ratio's own 0.277 of the practical 200 limit. This is a lightly-loaded column by design, with considerable spare margin to accept either a taller unbraced length or a genuine applied moment.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Compression/Tension Member module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Compression/Tension Member and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

How would a negative αb actually change the result for a cold-formed section?

Through λsl = λn + αaαb — a negative αb = −0.5 (Table 6.3.3's value for cold-formed hollow sections) actually reduces the effective slenderness used in the rest of the buckling chain relative to this hot-rolled example's αb = 0, which increases αc and the resulting capacity for the identical nominal slenderness.

Why does welding increase αb to +0.5 instead of leaving it at 0?

Welding introduces its own residual stress pattern into a built-up I-section beyond what rolling alone produces — Table 6.3.3 reflects this with a less favourable (positive) αb, genuinely reducing buckling capacity relative to an otherwise identical hot-rolled section at the same slenderness.

Final Thoughts

AS 4100's negative fabrication constant for cold-formed sections is a genuinely counterintuitive but deliberate feature of Table 6.3.3 — worth understanding explicitly rather than assuming it's an input error the first time it shows up in a calculation.