A timber roof truss's compression top chord, designed to China's GB 50005, checks buckling about both its strong and weak axes separately — a genuinely important distinction for a top chord, which typically has different lateral restraint conditions in each direction thanks to roof purlins bracing one axis but not necessarily the other.

Every check above runs automatically inside the Structyze Timber Roof Truss Member module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Top chord: TC15 sawn timber, 70 mm × 180 mm, unsupported length in-plane 2.4 m (between panel points), unsupported length out-of-plane 1.2 m (braced by purlins at closer spacing)
  • Design compressive strength f_c: 13 MPa
  • Design axial compression force: 24.5 kN

Working Through It

In-plane (about the 70 mm weak dimension, unbraced over the full 2.4 m panel length): slenderness ratio = 2400/(70/√12) = 118.8, giving a stability coefficient φ_weak ≈ 0.18 — a severe reduction at this high slenderness.

Out-of-plane (about the 180 mm strong dimension, braced by purlins at 1.2 m spacing): slenderness ratio = 1200/(180/√12) = 23.1, giving a stability coefficient φ_strong ≈ 0.81 — a much milder reduction thanks to the closer purlin bracing.

The lower of the two governs: φ = 0.18 (in-plane, weak-axis buckling).

Design axial capacity: 0.18 × 13 × (70 × 180) × 10⁻³ = 29.5 kN. Utilization: 24.5/29.5 = 0.83.

What Governs, and Why

In-plane, weak-axis buckling governs decisively at utilization 0.83, despite the purlin bracing giving the out-of-plane direction a dramatically milder reduction (φ = 0.81 versus 0.18) — a clear illustration that a member can have excellent restraint in one direction and still be governed entirely by a much more severe condition in the other, and that's why both axes need to be checked independently rather than assuming adequate bracing in one direction covers the member generally.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Timber Roof Truss Member module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Timber Roof Truss Member and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why would purlins brace the top chord out-of-plane but not in-plane?

Purlins typically run perpendicular to the truss, bracing the top chord against sideways (out-of-plane) movement at each purlin location, but they don't provide any restraint against the chord buckling within the plane of the truss itself, which remains governed by the panel point spacing between truss joints instead.

Would adding intermediate bracing within the truss plane improve this chord's capacity significantly?

Yes, likely substantially — since in-plane buckling is the clearly governing mode here, reducing that unsupported length (through additional diagonal or sub-member bracing within the truss plane) would squarely and significantly improve the chord's real governing capacity, more effectively than any change addressing the already well-restrained out-of-plane direction.

Final Thoughts

A top chord's buckling check needs two separate calculations, not one — and this example shows exactly why: excellent out-of-plane restraint from purlins did nothing to help the much more severe in-plane condition, which is precisely the governing check actually deciding this member's real capacity.