A reinforced concrete masonry unit (CMU) shear wall resisting lateral wind or seismic load is checked under TMS 402 against two genuinely separate failure modes — in-plane shear and combined axial-flexure at the wall base. And it's entirely possible for either one to govern depending on the wall's height-to-length proportions.
Every check above runs automatically inside the Structyze Masonry Shear Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Wall: 200 mm CMU, fully grouted, length 4.0 m, height 3.0 m
- f'm (masonry compressive strength): 13.8 MPa, vertical reinforcement: 16 mm bars at 600 mm c/c
- Factored in-plane shear demand: 95 kN, factored overturning moment at base: 165 kN·m
- Factored axial load from tributary gravity load: 180 kN
Working Through It
Shear capacity is checked first, combining the masonry's own contribution (based on net mortared cross-sectional area and f'm) with the horizontal shear reinforcement's contribution, following TMS 402's strength design shear equations — the combined calculated capacity for this wall works out to roughly 148 kN.
Utilization for shear: 95 / 148 = 0.64.
For the combined axial-flexure check at the wall base, the vertical reinforcement (16 mm at 600 mm c/c, fully grouted cells) combined with the 180 kN axial load gives a moment capacity of approximately 210 kN·m using a strain-compatibility approach similar in spirit to reinforced concrete wall design, adapted to masonry's compressive strength and reinforcement arrangement.
Utilization for combined axial-flexure: 165 / 210 = 0.79.
What Governs, and Why
Combined axial-flexure at the wall base governs at utilization 0.79, versus shear's 0.64 — a fairly typical outcome for a squat-to-moderate aspect ratio shear wall (height-to-length close to 0.75 here), where overturning moment tends to be the tighter check once enough shear reinforcement is already present to comfortably clear the shear demand.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Masonry Shear Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Masonry Shear Wall and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Does a squatter shear wall always mean shear governs instead of flexure?
Not automatically — a very squat wall (low height-to-length ratio) often does shift toward shear governing, but the actual outcome depends on the specific reinforcement provided for each check, not the aspect ratio alone.
Is grouting every cell always required for a masonry shear wall?
Not universally, but fully grouting a shear wall significantly increases both its shear and flexural capacity by engaging the full cross-section rather than just the grouted cells around reinforcement, which is why it's common for walls carrying significant lateral load.
Final Thoughts
A masonry shear wall's two governing checks — shear and base flexure — don't move in lockstep with each other — the reason both need an explicit calculation rather than assuming that clearing one comfortably means the other is automatically fine too.
[…] contribution together, following the same combined-contribution logic discussed for the TMS 402 reinforced shear wall example elsewhere in this […]