A purlin cleat's bolt grade choice alone can be the difference between a comfortable connection and a tight one — this module's Grade-4.6 default leaves noticeably less margin than a higher-strength Grade-8.8 bolt would at the identical M12 diameter, specifically as the companion bolted-connection chapter shows explicitly.
Every check above runs automatically inside the Structyze Purlin/Girt Cleat Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Factored reaction +15 kN (gravity, not uplift)
- Cleat thickness 8 mm, depth 120 mm
- Cleat material Fy = 250 MPa, Fu = 410 MPa
- Bolt M12, Grade 4.6, Fub = 400 MPa
- Edge distance 25 mm, pitch 45 mm; 2 bolts to purlin, 2 to support
Working Through It
The bearing geometry factor kb = min(e/3d0, p/3d0−0.25, fub/fu, 1.0) = min(0.641, 0.904, 0.976, 1.0) = 0.641, driven by the end-distance term.
Per-bolt capacity: shear governs decisively at 16.30 kN against a bearing capacity of 50.46 kN. Both bolt groups — cleat-to-purlin and cleat-to-support — check against the identical 15 kN reaction: 2(16.30) = 32.60 kN capacity, utilisation 0.460 on each side.
The cleat plate's own shear yielding, treated like a short beam web, carries wide margin: Vd = 960(250)/(√3×1.1)/1000 ≈ 126.0 kN against the 15 kN demand.
What Governs, and Why
Both bolt groups govern equally at utilisation 0.460, well ahead of the cleat plate's own shear capacity at 0.119 — a light, minimum-practical connection for a comparatively small purlin reaction, typical of roof secondary framing. As the Bolted/Welded Connection chapter in this series shows closely, the Grade-4.6 bolt default here leaves noticeably less margin than a Grade-8.8 bolt would at the same M12 diameter.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Purlin/Girt Cleat Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Purlin/Girt Cleat Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
How much would upgrading to Grade 8.8 actually change the margin?
Grade 8.8's ultimate strength (800 MPa) is specifically double Grade 4.6's 400 MPa — since both shear and bearing capacity scale directly with bolt ultimate strength, the same M12 bolt at Grade 8.8 would roughly double the per-bolt capacity, pushing utilisation down from 0.460 to somewhere near 0.230 for an identical connection layout.
Why does the reaction need to accept a signed value?
Wind uplift on a roof purlin reverses the usual downward gravity reaction into a net upward force — this module accepts a signed reaction (negative = uplift) and checks the identical three limit states regardless of direction, since the connection mechanics don't care which way the force points, only its magnitude.
Final Thoughts
Bolt grade selection is one of the cheapest levers available in a light connection like this — doubling the bolt's ultimate strength roughly doubles its capacity, often for a negligible cost difference over the whole project.