A combined footing's shear and moment diagram actually needs integrating, not just sampled at a couple of obvious points — Structyze's own engine builds the exact trapezoidal pressure and samples the diagram at 400 points specifically because the governing sagging and hogging moments don't always sit where intuition suggests.

Every check above runs automatically inside the Structyze Combined Footing module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Overhang 1.5 ft, column spacing 13 ft, overhang 3.5 ft
  • Footing 21.5 × 7 ft, thickness 22 in
  • Columns both 16 × 16 in
  • Column 1: dead 157 kip, live 79 kip — Column 2: dead 112 kip, live 56 kip
  • Allowable bearing 3.75 ksf

Working Through It

The load resultant sits at x̄ = 10.4 ft, giving eccentricity e = −0.35 ft against a middle-third limit of 3.58 ft — comfortably inside, and the resulting bearing pressure of 2.94 ksf stays under the 3.75 ksf allowable.

Integrating the exact diagram finds the hogging peak between the columns (M− ≈ −290 kip·ft total, 41 kip·ft/ft) and the sagging peak in the first overhang (M+ ≈ 340 kip·ft total, 49 kip·ft/ft) — bottom steel (0.59 in²/ft) and top steel (0.50 in²/ft) both size off these two truly different locations.

One-way shear, checked at d past column 1's face, runs close to its limit: 140 kip demand against 148 kip capacity, utilisation 0.94 — the tightest structural check in the whole design.

What Governs, and Why

One-way shear runs closest to its limit at utilisation 0.94 — a small increase in thickness or width would buy real margin here before anywhere else in the design. Punching at each column (0.58 and 0.40) and both flexure checks (0.67 and 0.80) all carry more comfortable reserve, confirming shear, not bending, is what would govern any further load increase on this geometry.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Combined Footing module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Combined Footing and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does the engine sample 400 points instead of just checking a couple of obvious locations?

A combined footing's moment diagram, built from a trapezoidal (not uniform) pressure distribution integrated against two discrete column loads, doesn't always peak at an intuitively obvious location — sampling densely and finding the true maximum and minimum is more reliable than assuming the peaks sit at midspan or directly under a column, especially once the pressure trapezoid and column spacing interact in a less symmetric way than this example's fairly balanced geometry.

What would push this design over on one-way shear?

Any increase in column load, a tighter allowable bearing pressure (forcing a smaller footing and less shear-resisting width), or a shorter overhang bringing the critical shear section closer to the column face would all push the already-tight 0.94 utilisation over 1.0 — thickness or width, not bar area, would be the fix.

Final Thoughts

A combined footing's one-way shear check running at 0.94 while every other check has real margin is a useful reminder that a footing's overall 'looks fine' impression can hide one number sitting much closer to the edge than the rest.