NBR 6118 doesn't publish its own two-way moment-coefficient table the way IS 456 or CSA A23.3 do — Brazilian practice instead relies on widely used Marcus-table-style representative coefficients, a really different sourcing convention worth understanding before trusting a number off any single table.

Every check above runs automatically inside the Structyze RCC Slab module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The Example We'll Use

  • Panel (clear) 4 × 5 m, all edges continuous
  • Thickness 150 mm, cover 20 mm (CAA I)
  • Permanent (SDL) 1.5 kN/m², variable 3 kN/m²
  • Concrete C20, steel CA-50
  • Reinforcement 8 mm bars at 175 mm both directions (bottom); top steel at supports

Working Through It

Aspect ratio r = 5/4 = 1.25, under 2 — truly two-way. Factored load wd = 1.4(25×0.15+1.5+3) ≈ 11.55 kN/m², using NBR 6118's own 1.4 factor rather than the 1.5 many other codes apply to live load specifically.

Using representative Marcus-style coefficients for the short-span support moment (αx− = 0.055), Mx− = 0.055(11.55)(4)² ≈ 10.16 kN·m/m. Working this through NBR 6118's own flexure formulation gives a required Ast of about 192 mm²/m — below the Cl 17.3.5 minimum of 225 mm²/m, so minimum steel governs the bar count.

Deflection uses a distinctly generous screening ratio for two-way slabs (35, versus a materially tighter ratio this book applies to beams) — reflecting the lower stress level typical of a thin, lightly-reinforced slab. At L/d = 32, the slab clears this with real but not huge margin.

What Governs, and Why

Deflection governs at utilisation 0.91, the tightest of the four checks, closely followed by bar spacing (0.88) and minimum steel (0.78). This is the familiar pattern across every slab chapter in this series: serviceability, not calculated bending strength, sets the thickness.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze RCC Slab module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The free trial covers a curated set of flagship modules including this one. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why doesn't NBR 6118 publish its own two-way coefficient table?

Unlike IS 456's Annex D or similarly tabulated codes, Brazilian practice for two-way slab moment coefficients has historically relied on widely used reference tables (the Marcus method and its variants) rather than a table embedded squarely in the code text itself — this book uses representative values from that established practice as a disclosed stand-in.

Does NBR 6118 require a more rigorous deflection calculation?

Yes — formally, NBR 6118 Cl 13.3 calls for a full immediate-plus-creep deflection calculation, not just a span/depth screening ratio. This book's simplified ratio is a faster preliminary check; a final design should verify against the full calculation where deflection runs close to its limit.

Final Thoughts

NBR 6118's reliance on external representative tables for two-way moment coefficients, rather than a code-embedded table, is a different sourcing convention from IS 456 or CSA A23.3 — worth knowing which table your numbers actually come from.