A silo wall's pressure isn't the simple triangular distribution a water tank or retaining wall uses — stored granular material (grain, cement, aggregate) develops internal friction against the wall as it settles, which Janssen's theory captures as a pressure that asymptotically approaches a constant value with depth rather than growing linearly forever the way hydrostatic pressure does.

Every check above runs automatically inside the Structyze RCC Silo module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Silo internal diameter 6.0 m, storage height 15.0 m
  • Stored material: unit weight 8.0 kN/m³, internal friction angle 30°, wall friction coefficient 0.4
  • Wall thickness 250 mm, M30/Fe415
  • Flat base slab, conservatively assumes full material column rests on base

Working Through It

Janssen's equation gives horizontal wall pressure ph = (γR/2μ)(1 − e−2μKz/R), where K is the ratio of horizontal to vertical pressure (from the material's friction angle) and μ is the wall friction coefficient — this asymptotes toward a maximum value well before reaching the full 15 m depth, in sharp contrast to a water tank's pressure that keeps growing linearly to the very base.

Hoop tension in the wall at any depth follows the same ring-tension logic as a circular water tank (T = ph × R), but using this Janssen-derived pressure rather than hydrostatic pressure — checked against reinforcement capacity and, since this is a dry-material silo rather than a liquid-retaining structure, without the tank's tighter crack-width serviceability limit.

The base slab is checked for bearing pressure from the stored material — this module conservatively assumes the full material column's weight rests directly on the base (rather than crediting the wall friction that Janssen's own theory says carries part of that weight vertically via the walls), which is why base bearing comes out as the governing check at a relatively high utilisation of roughly 0.88.

What Governs, and Why

Base bearing governs at utilisation 0.88, a direct consequence of this module's conservative assumption that the entire stored material weight bears on the base slab rather than crediting any of Janssen's own wall-friction load transfer — a deliberately safe simplification that trades some economy for confidence, worth knowing explicitly before assuming the real base pressure is this high.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze RCC Silo module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For RCC Silo and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does Janssen's pressure level off with depth instead of growing forever like water pressure?

As stored material settles under its own weight, friction against the silo wall progressively picks up an increasing share of the vertical load, transferring it out horizontally and, crucially, down through the wall to the base via friction rather than through the material column squarely — this wall-friction effect is exactly what caps horizontal pressure at a roughly constant asymptotic value rather than letting it grow linearly with depth the way hydrostatic pressure (with no internal friction) does.

If wall friction carries some of the material's weight, why does the base bearing check assume it all reaches the base anyway?

This is the module's disclosed conservative simplification: properly crediting wall friction's vertical load transfer would require a more detailed free-body analysis of the wall itself carrying vertical friction-induced load down to its own foundation, which is a materially more involved calculation than this module currently performs. Assuming the full material column's weight reaches the base instead is conservative (it overstates base pressure), which is safe but means the true base bearing demand in a real silo may be somewhat lower than this check reports.

Final Thoughts

Janssen's pressure theory is one of the more distinctive pieces of structural mechanics in this entire series — different physics from any liquid-retaining or earth-retaining structure covered elsewhere, driven by internal material friction rather than simple fluid or soil pressure.