A hopper is the structural opposite of a dome — where a dome arches in compression, a hopper hangs entirely in tension, with both its hoop and meridional forces tensile everywhere, meaning the plate needs real reinforcement in both directions, not just a minimum mesh in one.

Every check above runs automatically inside the Structyze RCC Hopper module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Top (support-ring) diameter 4 m (R = 2 m); outlet diameter 0.6 m
  • Half-angle from vertical 25°; plate thickness 150 mm
  • Equivalent head above hopper 12 m
  • Stored material γ = 16 kN/m³, Kb = 0.276
  • Concrete M25, steel Fe415

Working Through It

The slant length L = vertical drop/cosα ≈ 4.02 m, giving a lateral surface area of about 29.1 m². Design pressure pn = Kbγz0 ≈ 53.0 kN/m², reusing the bunker's Airy ratio convention.

Hoop tension, maximum at the top where the hopper is widest: Nθ,u = 1.5pnR/cosα ≈ 175.5 kN/m, requiring 486 mm²/m — well above the 180 mm²/m minimum, so calculated strength really governs here, covered by 12 mm bars at 250 mm each face.

Meridional tension, from the hopper's own content-plus-self-weight hanging from the support ring: Nφ,u ≈ 52.1 kN/m, requiring only 144 mm²/m — this time below the minimum, so the code floor governs the meridional steel instead.

What Governs, and Why

Hoop tension — from the lateral material pressure, at its maximum where the hopper is widest. Governs over the meridional (weight-carrying) tension at utilisation 0.54. Unlike a dome, where only the lower band needs tension steel for strength, a hopper's plate is tensile everywhere, so both directions need reinforcement, not minimum mesh in one direction and strength steel in the other.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze RCC Hopper module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For RCC Hopper and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why is a hopper's hoop force always tensile, unlike a dome's?

A dome's shape curves the shell inward toward the crown, so the hoop direction stays in compression near the top and only turns tensile past a critical angle; a hopper's conical shape flares outward from a narrow outlet to a wide support ring, so the hoop direction is under outward tension at every level — a direct consequence of the cone's geometry, not the loading.

What is the junction bending check, and why does it barely matter here?

It's the local bending disturbance at the kink where the near-vertical bin wall above meets the steeply sloped hopper below — a representative moment analogous to a tank's wall-base junction. Here it works out to just 78 mm²/m required, far below the 180 mm²/m minimum already provided by the hoop and meridional steel continuing through the junction, so it's essentially a non-issue for this geometry.

Final Thoughts

A hopper needing tension steel in both directions, rather than compression in one and minimum steel in the other, is the clearest structural distinction between it and the dome it superficially resembles.