AS 3600's kv shear-strength factor is capped at 0.10 regardless of how favourable the raw calculation comes out — a code-specific ceiling that keeps the one-way shear capacity from climbing indefinitely as depth increases, and it's what governs this footing's thickness.
Every check above runs automatically inside the Structyze Isolated Footing module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.
The Example We'll Use
- Column 400 × 400 mm
- Footing 2.6 × 2.6 m, thickness 450 mm
- Cover 60 mm (cast against blinding)
- Axial: permanent 600 kN, variable 300 kN
- Allowable bearing 150 kN/m²; materials N40, 500N
Working Through It
Service bearing q = 900/2.6² ≈ 133 kN/m² against 150 kN/m² allowable. Design pressure uses the governing load combination: N* = max(1.35NG, 1.2NG+1.5NQ) = 1170 kN, giving qu ≈ 173 kN/m².
One-way shear: the raw kv = 200/(1000+1.3dv) works out to 0.139, but AS 3600 caps it at 0.10 — that cap, not the raw formula, sets φVuc ≈ 415 kN against a demand of 327 kN (utilisation 0.79, the governing check).
Punching shear, using fcv = 0.34√f′c ≈ 2.15 MPa, gives φVuo ≈ 1868 kN against 1066 kN demand (utilisation 0.57) — comfortable margin. Bending comes out governed by the Cl 8.1.6.1 minimum (822 mm²/m) rather than calculated demand.
What Governs, and Why
One-way shear governs the thickness at utilisation 0.79 — the kv cap at 0.10 is what actually sets this, not the section depth or steel ratio squarely. AS 3600's φVuc formula sits between the Eurocode vmin and the CSA β√f′c terms for this same geometry, so this footing needs no extra depth over the equivalent ACI design elsewhere in this series.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Isolated Footing module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.
The free trial covers a curated set of flagship modules including this one. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why cap kv at 0.10 instead of letting the formula run freely?
The kv = 200/(1000+1.3dv) formula would otherwise predict an ever-more-generous shear stress limit for a shallower effective depth, which isn't physically realistic beyond a certain point — the 0.10 cap keeps the shear strength calculation from over-crediting truly thin sections.
How does this compare to the identical footing under ACI 318 or Eurocode 2?
AS 3600's shear provisions here land between the Eurocode 2 vmin term and the CSA A23.3 β√f′c approach for this same geometry — none of the three codes need a materially different thickness for the identical loads, a useful cross-check that the codes, despite their different formula structures, converge on comparable practical outcomes for an ordinary footing.
Final Thoughts
The kv cap is a small, easy-to-miss detail in AS 3600's shear provisions — skip it and a hand calculation could overstate the footing's real shear capacity without ever noticing the ceiling should have applied.