A cap plate connection is really three independent checks stacked together — the plate's own bending, the plate-to-column perimeter weld, and the chord-to-plate connection. Each reusing established mechanics from elsewhere in this series rather than needing any new theory.
Every check above runs automatically inside the Structyze HSS Cap Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Column tube 150 mm, chord tube width 150 mm (both SHS)
- Factored reaction 100 kN
- Cap plate 220 × 220 × 12 mm, fy = 300 MPa, fu = 440 MPa
- Chord-to-plate connection: welded, 6 mm SP fillet, fuw = 480 MPa
Working Through It
Bearing pressure fp = 100×1000/(220×220) ≈ 2.066 MPa. With a square column and plate, the critical projection n = 35.0 mm on each side. Reusing the identical cantilever-strip formula from the Base Plate module: tp,req = 35.0√(2(2.066)/(0.9×300)) ≈ 4.33 mm against the 12 mm provided.
Cap-to-column weld: perimeter 600 mm, φvw ≈ 0.978 kN/mm, capacity ≈ 586.6 kN against the 100 kN demand. The chord-to-plate weld, sharing identical tube size and weld category, lands at the same capacity.
What Governs, and Why
Plate bending governs at utilisation 0.361, more than double either weld's own margin (0.170 each) — with equal column and chord tube sizes, the two perimeter welds come out numerically identical, a direct consequence of the shared 150 mm tube size and matching 6 mm weld leg on both.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze HSS Cap Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For HSS Cap Plate Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why does this module get described as 'three checks stacked together' rather than one unified calculation?
Each of the three checks — plate bending, cap-to-column weld, chord-to-plate connection — addresses a truly different potential failure location along the load path, and each uses its own established method (cantilever-strip bending, weld strength per unit length, full-reaction bolt or weld design) rather than a single combined formula. Recognising them as independent, stackable checks is the clearest way to understand why the connection needs all three verified separately.
What isn't checked here that a more complete design might need?
Local crushing or punching of the hollow column's own tube wall under the concentrated cap-plate reaction isn't separately checked — only the plate's own bending and the two weld/connection checks are covered by this simplified method.
Final Thoughts
Seeing a cap plate connection resolve cleanly into three independently-checkable pieces, each borrowing established mechanics from elsewhere, is a useful way to understand how a seemingly complex connection detail is really just three simpler problems in sequence.