A tube-on-tube cap plate under CSA S16 reuses the identical one-way cantilever-strip formula already established for a wide-flange base plate — the bearing-pressure-under-a-plate mechanics don't care whether the load comes from a column on concrete or a chord on a column tube.
Every check above runs automatically inside the Structyze HSS Cap Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Column tube 150 mm, chord tube width 150 mm (both square SHS)
- Factored reaction 100 kN
- Cap plate 220 × 220 × 12 mm (provided), Fy = 350 MPa
- Welded connection: cap-to-column and chord-to-plate, both 6 mm, Fu = 490 MPa
Working Through It
Bearing pressure under the cap plate: fp = 100,000/(220×220) ≈ 2.07 MPa. With a square column centred on a square plate, the critical projection l = 35 mm.
Reusing the base-plate cantilever-strip formula: tp,req = 35√(2(2.07)/(0.9×350)) ≈ 4.01 mm against the 12 mm provided — utilisation 0.334, wide margin.
Both perimeter welds — cap-to-column and chord-to-plate — share identical geometry here (same 150 mm tube, same 6 mm weld), landing at the same comfortable utilisation of 0.080.
What Governs, and Why
Cap plate bending governs at utilisation 0.334, the tightest of the three checks but still with wide margin — both perimeter welds run at the lighter 0.080. All three checks pass with substantial reserve, typical of a lightly-loaded truss-to-column bearing detail.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze HSS Cap Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For HSS Cap Plate Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why does this connection reuse the base-plate formula rather than deriving a tube-specific one?
The underlying bearing-plate mechanics — a plate cantilevering out from whatever member sits beneath it, resisting uniform bearing pressure — don't depend on whether that member is a wide-flange column bearing on a concrete pedestal or a tube column bearing a tube chord. Reusing the established one-way cantilever-strip formula for a structurally analogous problem is deliberate, not a shortcut.
What assumption does this check rely on for a rectangular (non-square) column tube?
Both the cap-to-column weld perimeter calculation and the plate-bending projection assume a square SHS column with identical projections on every side; a rectangular column would need the actual perimeter and the two genuinely different projections substituted in, rather than assuming symmetry the way this square-on-square example allows.
Final Thoughts
This cap plate connection is a clean example of a formula travelling cleanly from one structural context (wide-flange base plate) to a really different one (tube-on-tube bearing) without needing any real modification.