A cap plate connecting a tube truss chord to a tube column reuses the exact same bearing-plate mechanics as a concrete base plate — the cantilever-strip bending formula doesn't care what's generating the bearing pressure underneath it, only the geometry of the projection beyond the supporting member.
Every check above runs automatically inside the Structyze HSS Cap Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Column tube 150 mm, chord tube width 150 mm (both square SHS)
- Factored reaction 100 kN
- Cap plate 220 × 220 × 12 mm (provided), Fy = 345 MPa
- Welded connection: cap-to-column and chord-to-plate, both 6 mm, E70XX
Working Through It
Bearing pressure under the cap plate: fp = 100,000/(220×220) ≈ 2.07 MPa. The critical cantilever projection — how far the plate extends beyond the square column tube's profile. Is just 35 mm on each side.
Running the identical cantilever-strip formula from the concrete base-plate chapter, tp,req = 35√(2(2.07)/(0.9×345)) ≈ 4.04 mm, against the 12 mm plate actually provided — utilisation 0.337, plenty of reserve.
Both perimeter welds — cap-to-column and chord-to-plate. Happen to share identical geometry here (same 150 mm tube size, same 6 mm weld), so both come out at the same comfortable utilisation of 0.120.
What Governs, and Why
Cap plate bending governs at utilisation 0.337, the tightest of the three checks but still with wide margin — both perimeter welds run at the lighter 0.120. All three checks pass with substantial reserve, typical of a lightly-loaded truss-to-column bearing detail.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze HSS Cap Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For HSS Cap Plate Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why does this connection use the same formula as a concrete base plate?
The underlying mechanics — a plate cantilevering out under uniform bearing pressure from the member it sits on. Are structurally identical whether the pressure comes from bearing on a concrete pedestal or from a tube chord bearing on a tube column; reusing the established formula rather than deriving a new one reflects that the physics, not the material underneath, drives the check.
Why is the chord-to-cap-plate connection designed for the full reaction?
Because direct bearing between chord and cap isn't guaranteed to reliably transfer gravity load on its own — under certain conditions (like wind uplift), the chord could separate from the plate, so designing the weld or bolt connection for the full factored reaction in shear is the conservative, and in some load cases the truly governing, approach.
Final Thoughts
Reusing the base-plate cantilever-strip formula for a tube-to-tube cap plate is a clean example of how the same underlying mechanics show up across structurally different-looking connections once you recognize the pattern.