AS 4100's gusset plate check runs at the tightest margin of any connection chapter in this whole series — 0.928 utilisation at the software's own default inputs — actually close to failing, though it stays just under 1.0 unlike the identical geometry checked under a lower-strength material elsewhere in this series.

Every check above runs automatically inside the Structyze Truss Gusset Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Bolted connection, 3 members (chord + diagonal) at the joint
  • Gusset 10 mm, fy = 300 MPa, fu = 440 MPa
  • Bolt M20, Grade 8.8, fuf = 830 MPa
  • Edge distance 35 mm, pitch 60 mm
  • Member forces: top chord +150 kN, bottom chord −120 kN, diagonal +80 kN (4 bolts each)

Working Through It

Each member's own bolt group checks comfortably: governing capacity per bolt 97.0 kN (shear governs), group capacity 388.0 kN — the top chord (150 kN) runs at just utilisation 0.387, wide margin.

The governing member is the top chord. Net-section tension uses an effective width of 70 mm (twice the edge distance); after deducting the 22 mm bolt hole, net area is 480 mm². Yield capacity φNt ≈ 189.0 kN; fracture capacity φNtf ≈ 161.6 kN — fracture governs.

161.6 kN against the 150 kN demand gives utilisation 0.928 — the tightest check at this joint by a wide margin over block shear (0.190) and every bolt group.

What Governs, and Why

The gusset plate's own net-section fracture is the tightest check at the joint (utilisation 0.928) even though every bolt group and block shear both carry real margin. AS 4100's combination of a lighter 0.85 fracture factor (versus Eurocode 3's γM2 = 1.25 divisor) and this default's higher-strength fu = 440 MPa plate keeps it just under 1.0 — a actually tighter check than the bolt groups, but not, at this code's own numbers, a failing one.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Truss Gusset Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Truss Gusset Plate Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does the identical joint geometry fail under Eurocode 3 but pass (barely) under AS 4100?

The combination of a lower fracture reduction factor and a lower-strength plate grade under EC3's version of this same joint pushes its net-section check over 1.0, while AS 4100's lighter 0.85 factor and this example's higher fu = 440 MPa plate keep the identical geometry just under the limit — a genuine, code-specific difference in calibration and material grade, not an inconsistency in either calculation.

What would restore more comfortable margin on this joint?

Increasing the edge distance (widening the effective width beyond 70 mm), increasing the gusset thickness, or moving to two bolt rows would each add real reserve — any change needs verifying against every other check, since a thicker or wider plate also shifts the block-shear areas.

Final Thoughts

Running the same joint geometry across AS 4100 and its Eurocode 3 counterpart elsewhere in this series shows exactly how close 'passes' and 'fails' can sit for a gusset plate — a few percentage points of fracture-factor calibration is the entire difference.

One thought on “How to Design a Truss Gusset Plate Connection to AS 4100 (Step by Step, With Free Software)”

Leave a Reply

Your email address will not be published. Required fields are marked *