A glulam timber column under axial compression, designed to Eurocode 5 (EN 1995-1-1), hinges on a buckling reduction factor k_c that plays the same structural role as the steel column curves covered elsewhere in this series — except timber's own material variability feeds directly into how that factor is calculated.
Every check above runs automatically inside the Structyze Timber Column module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Column: glulam GL24h, 140 mm × 280 mm, height 3.6 m, pinned-pinned effective length factor 1.0
- Characteristic compressive strength parallel to grain, f_c,0,k: 24 MPa
- Design axial load N_d: 185 kN, load duration class: medium-term, service class 1
- k_mod (load duration and moisture modification factor): 0.8, partial factor γ_M: 1.25
Working Through It
Slenderness ratio about the weak axis: effective length / radius of gyration = 3600 / (280/√12) = 44.5, a moderate value typical of a reasonably proportioned glulam column.
Relative slenderness ratio λ_rel is calculated by normalizing against the material's own characteristic strength and stiffness (E_0.05), giving λ_rel ≈ 0.78 for this column — placing it in the range where buckling reduction meaningfully governs rather than being negligible.
The buckling reduction factor k_c is then derived from λ_rel through Eurocode 5's column curve formulation (analogous in spirit to the steel column curves but calibrated for timber), giving k_c ≈ 0.73 for this slenderness.
Design compressive strength = k_mod × f_c,0,k / γ_M = 0.8 × 24 / 1.25 = 15.4 MPa.
Design buckling resistance = k_c × design compressive strength × cross-sectional area = 0.73 × 15.4 × (140 × 280) = 440 kN.
Utilization: N_d / design resistance = 185 / 440 = 0.42.
What Governs, and Why
Buckling resistance governs comfortably at utilization 0.42, with the k_c factor responsible for roughly a 27% reduction off the column's non-slender compressive capacity — a reminder that even a moderately slender glulam section loses a meaningful chunk of its raw material strength to buckling effects well before slenderness becomes visually dramatic.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Timber Column module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Timber Column and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why does k_mod depend on load duration for timber specifically?
Timber exhibits a well-documented reduction in long-term strength under sustained load (a creep-rupture effect), so Eurocode 5 assigns a lower k_mod to longer load duration classes and a higher one to short-duration loads, reflecting wood's distinct time-dependent strength behavior compared to steel or concrete.
Does service class affect anything beyond k_mod?
Yes — service class (reflecting ambient moisture conditions) also affects the characteristic stiffness values used in the slenderness and buckling calculations, since timber's stiffness and strength are both moisture-sensitive in a way steel's aren't.
Final Thoughts
A timber column's buckling check folds together slenderness, like any compression member, with timber-specific factors for load duration and moisture service class that have no real equivalent in steel design, and that's why the same column dimensions can carry a different allowable load purely because of how long its governing load case lasts or how damp its service environment is.