NZS 3404 governs the steel side of a base connection but is entirely silent on concrete bearing — so this module reaches across the Tasman into AS 3600:2018 Cl 12.3 for the pedestal bearing check, the same simplification this app's CSA S16 and IS 800 base-plate engines already use for an analogous gap.

Every check above runs automatically inside the Structyze Base Plate module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Column 250 × 250 mm
  • Plate 450 × 450 × 32 mm (provided)
  • Axial: dead 300 kN, live 200 kN
  • Pedestal concrete N32, f′c = 32 MPa
  • Plate material fy = 300 MPa

Working Through It

The governing factored load compares two combinations: 1.35G alone (405.0 kN) against 1.2G+1.5Q (660.0 kN) — the live-load-inclusive case governs. Bearing pressure fp = 660.0×1000/(450×450) ≈ 3.259 MPa.

Borrowing AS 3600:2018 Cl 12.3's unconfined bearing check (no separate pedestal footprint, so no confinement credit): φNbz = 0.65(0.85)(32) ≈ 17.68 MPa, utilisation just 0.184.

Plate thickness, using the identical cantilever-strip formula every base plate module in this series shares: tp,req = 100.0√(2(3.259)/(0.9×300)) ≈ 15.54 mm against the 32 mm provided.

What Governs, and Why

Plate bending governs at utilisation 0.486, well ahead of concrete bearing's 0.184 — with the plate sized only 100 mm larger than the column profile on each side and a generous 32 mm provided thickness, this base has real spare margin in both checks.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Base Plate module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Base Plate and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why would a steel design code need to borrow from a concrete code at all?

NZS 3404 is scoped to steel member and connection design; the bearing strength of the concrete pedestal underneath a base plate is fundamentally a concrete design question that NZS 3404 simply doesn't address. Reaching into AS 3600 (the sibling concrete code under the same joint Australia/New Zealand standards framework) for that one check is a practical, disclosed solution rather than leaving the check undone.

Is this the same pattern seen elsewhere in this series?

Yes — CSA S16's base plate module borrows from CSA A23.3, and IS 800's borrows from IS 456, for the same reason: a steel code checking bearing against concrete needs a concrete-code bearing provision, and each pairing reaches for its own natural sibling code rather than inventing a redundant one.

Final Thoughts

A steel base plate module quietly reaching into a concrete code for the one check it can't cover itself is a consistent pattern across this whole series — worth recognising as a deliberate, sensible division of labour rather than a gap.