IS 800 handles a tension-zone bolt's combined tension and shear with a quadratic interaction ellipse — architecturally different from AISC 360's approach of reducing the available tensile stress itself, though both are legitimate ways of combining the same two demands.
Every check above runs automatically inside the Structyze Moment End-Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Member 400 × 200 × 12 × 8 mm, Fy = 250 MPa, Fu = 410 MPa
- Factored moment 120 kN·m, shear 80 kN
- End plate 32 mm, Fy = 250 MPa
- 4 × M24 Grade 8.8 bolts (tension zone), pitch 90 mm
- Lever arm 360 mm, cantilever projection 50 mm
Working Through It
Bolt tension from the couple: T = 120,000/360 ≈ 333.3 kN total, Tbolt = 83.33 kN per bolt; Vbolt = 20 kN. Bolt capacities: Tdb ≈ 203.3 kN, Vdb ≈ 130.4 kN (both using the 0.78 net-area convention on the Grade 8.8 bolts).
The quadratic interaction, (Vbolt/Vdb)² + (Tbolt/Tdb)² = (20/130.4)² + (83.33/203.3)² ≈ 0.0235 + 0.1681 = 0.192 — comfortable, since squaring both ratios shrinks their combined contribution relative to a linear sum.
End plate bending, treq = √(4(46.30)(1.1)/250) ≈ 28.55 mm against the 32 mm provided, is the tightest check at utilisation 0.892 — the same pattern this series' AISC 360 companion finds for its own version of this connection (0.763 there), with a compact 4-bolt tension zone typically leaving the plate itself, not the fasteners, as the binding constraint.
What Governs, and Why
End-plate bending governs at utilisation 0.892, well ahead of every bolt and weld check. The Grade-8.8 bolts chosen here carry generous margin (0.192) precisely because they're the higher of the two grades this module offers — a Grade-4.6 default would run far tighter for a comparable demand, exactly as the Bolted/Welded Connection chapter in this series shows explicitly.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Moment End-Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Moment End-Plate Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
How is IS 800's quadratic interaction different from AISC 360's approach to the same problem?
AISC reduces the bolt's available tensile stress itself based on how much shear it already carries, then compares demand against that reduced value directly; IS 800 (and CSA S16, AS 4100) instead check both ratios squared and summed against 1.0 — an ellipse rather than a stress-reduction line. Both are code-sanctioned, and for a bolt with a small shear-to-tension ratio (like this one), the quadratic form is genuinely easier to evaluate by hand.
Does IS 800 check prying action?
No — IS 800:2007 doesn't codify a prying-force formula the way Eurocode 3 or BS 5950 do. Prying action can meaningfully increase bolt tension beyond the simple Tbolt value for a flexible end plate; keeping the plate reasonably stiff relative to the bolt gauge, or consulting a specialist connection reference, covers that gap.
Final Thoughts
IS 800's quadratic bolt-interaction ellipse is a genuinely different mathematical approach from AISC 360's stress-reduction method, even though both are answering the identical combined tension-and-shear question.
[…] S16 uses the identical quadratic interaction ellipse as IS 800 for a bolt's combined tension and shear — architecturally different from AISC 360's […]