Where column loads or spacing differ meaningfully across a raft, the rigid flat-slab idealisation gets too crude — the strip method instead isolates one representative column-line strip and integrates its exact shear and moment diagram, the same way a combined footing analysis would, just extended across three or more columns.

Every check above runs automatically inside the Structyze Mat Foundation module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Three-column strip: overhang 1 m, spacing 5 m, spacing 5 m, overhang 1 m
  • Strip width 3 m, thickness 700 mm
  • Columns 400 × 400 mm; cover 50 mm
  • Column loads (permanent/variable): A & C 600/300 kN, B 900/450 kN
  • Allowable bearing 150 kN/m²; concrete C30/37, steel B500

Working Through It

With symmetric loads and geometry, the eccentricity comes out essentially zero and the service bearing pressure, q = 3150/(12×3) ≈ 87.5 kN/m², clears the 150 kN/m² allowable with real margin (utilisation 0.58).

Sampling the exact moment diagram along the strip finds a hogging peak between columns A and B of about 901 kN·m total (300 kN·m/m across the 3 m width, the top steel), and a sagging peak near mid-span of about 315 kN·m total (105 kN·m/m, bottom steel). The top steel comes out governed by calculated bending (utilisation 0.72); the bottom steel, at only 396 mm²/m required, is instead governed by the Cl 9.2.1.1 minimum of 968 mm²/m — and running very close to it, at utilisation 0.96.

One-way shear, sampled just before the heavily-loaded column B, comes in at 636 kN against a capacity of 719 kN (utilisation 0.88) — the tightest structural check in the strip, consistent with the pattern across every Eurocode 2 footing in this series, where shear without links tends to set the thickness.

What Governs, and Why

One-way shear governs at utilisation 0.88, with the bottom-steel minimum running a very close second at 0.96 (though that's a minimum-steel check, not a strength limit). The 700 mm strip depth ends up 200 mm deeper than the equivalent ACI-designed raft for similar loads — a direct consequence of Eurocode 2's shear provisions carrying no link reserve the way ACI's could with stirrups.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Mat Foundation module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Mat Foundation and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why use the strip method instead of the simpler rigid method here?

The rigid (flat-slab) method assumes a planar contact pressure, which is a reasonable approximation for a fairly uniform grid and load pattern — but once column loads genuinely differ (600/300 vs 900/450 kN here), the true pressure distribution along a strip becomes meaningfully non-planar, and the strip method captures that exact trapezoidal variation instead of averaging over it.

What would change with a less symmetric loading?

An asymmetric column-load pattern would shift the pressure resultant off-centre, introducing a genuine eccentricity check (middle-third) on top of the shear and moment sampling shown here — the same combined-footing-style eccentricity logic, just extended across more columns.

Final Thoughts

Sampling an exact shear and moment diagram along a three-column strip by hand, rather than approximating with the rigid method's uniform pressure, is the kind of numerically tedious work that's important to automating.

Leave a Reply

Your email address will not be published. Required fields are marked *