A crane gantry girder needs genuinely biaxial bending checked at once — a large vertical moment from the wheel load plus impact, and a smaller but structurally independent lateral moment from crane surge. And the same 1.2Zefy/γm0 plasticity cap that rarely governs major-axis bending in an ordinary beam very often does govern the minor axis here.

Every check above runs automatically inside the Structyze Gantry Girder module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Span 6 m
  • Section 450 × 200 × 20 × 12 mm
  • Maximum static wheel load 100 kN
  • Vertical impact factor 25%, lateral surge 10% of wheel load
  • Material Fe410 (E250), fy = 250 MPa

Working Through It

Factored wheel load Wu = 1.5(100)(1.25) = 187.5 kN; factored surge Su = 1.5(100)(0.10) = 15 kN. Using the single moving-point-load approximation, Muz = 187.5(6)/4 = 281.25 kN·m (major axis) and Muy = 15(6)/4 = 22.5 kN·m (minor axis, from surge).

On the major axis, the plain plastic-moment term (505.5 kN·m) governs over the 1.2Zefy/γm0 cap (532.0 kN·m) as usual. But on the minor axis, the shape factor Zpy/Zey = 1.552 — well above 1.2 — flips this: the cap (72.89 kN·m) is now lower than the plain plastic term (94.26 kN·m) and governs instead.

The combined biaxial check, Muz/Mdz + Muy/Mdy, comes to 0.556 + 0.309 = 0.865 — and that second term is meaningfully larger than a 10% surge allowance alone would suggest, precisely because the minor-axis capacity it's divided by has already been knocked down by the plasticity cap.

What Governs, and Why

The combined biaxial check governs at utilisation 0.865, dominated by the vertical wheel-load term but with the surge term contributing more than its modest 10% load ratio implies — a direct consequence of the 1.2Ze cap reducing minor-axis capacity below its plain plastic value. A girder proportioned mainly for vertical load will generally show this same pattern.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Gantry Girder module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Gantry Girder and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does the plasticity cap bite on the minor axis but not the major axis?

An I-section's minor-axis shape factor (Zpy/Zey) is typically much higher than its major-axis shape factor, because the section is far less efficient bending about its weak axis — when that ratio exceeds 1.2, the code's cap on assumed plastic-zone spread overtakes the plain plastic moment as the binding limit.

What's the major scope limitation in this hand method?

The single moving-point-load approximation (Mmax = PL/4) is exact only for a wheelbase small relative to the span — a real two-wheel bogie with a wheelbase comparable to the span needs the true governing load position found separately.

Final Thoughts

A gantry girder is one of the few steel members where checking 'just the major axis' by hand actually misses the governing check — the minor-axis surge term deserves the same care as the vertical load.

Leave a Reply

Your email address will not be published. Required fields are marked *