A rod brace's governing failure mode under NZS 3404 comes down to a truly close race between gross-section yield and net-section fracture — the 0.78 net-area factor and the 0.85 fracture factor together very nearly offset the higher ultimate stress relative to yield stress, a close-run pair typical of a threaded rod at this diameter.
Every check above runs automatically inside the Structyze Bracing Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Brace type: rod, factored tension 60 kN
- Rod diameter 20 mm, fy = 300 MPa, fu = 440 MPa
- End connection: bolted, M20 Grade 8.8, 2 bolts
- Gusset thickness 10 mm, fu = 440 MPa
Working Through It
The rod's gross area Ag ≈ 314.2 mm², net area at the threaded root An = 0.78(314.2) ≈ 245.0 mm² — the standard geometric convention used across every code in this series.
Two capacities compete: φNt = 0.9(314.2)(300)/1000 ≈ 84.8 kN (yield) versus φNtf = 0.9(0.85)(245.0)(440)/1000 ≈ 82.5 kN (fracture). Fracture governs, narrowly — the two capacities sit within about 3% of each other.
The end connection carries far more relative margin: governing per-bolt capacity 97.0 kN, group capacity 194.0 kN against the 60 kN demand — utilisation 0.309, well under the rod's own 0.727.
What Governs, and Why
The rod itself governs at utilisation 0.727, not its end connection (0.309) — and within the rod check, fracture at the threaded root (82.5 kN) governs only narrowly over gross-section yield (84.8 kN). This close pairing reflects how the 0.78 net-area factor and the 0.85 fracture factor together very nearly offset the higher fu versus fy for this particular material grade.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Bracing Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Bracing Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why are yield and fracture capacity so close together for this rod?
The net-area reduction (0.78) and the fracture reduction factor (0.85) combine to roughly a 0.66 multiplier on the gross-section-equivalent capacity at fu, while yield uses the full gross area at fy directly — for a material grade where fu/fy happens to sit near 1.47, these two effects very nearly cancel, producing the close race seen here rather than a clear winner.
Does NZS 3404 apply any shear-lag reduction for a single-angle brace?
No — this module's disclosed gap is that for the single-angle branch, NZS 3404's own kt reduction (Table 7.3.2) for a connection through only one leg isn't applied, since it isn't confidently derivable without a primary-source table lookup. This makes that branch's fracture capacity non-conservative for a single-angle-through-one-leg connection; verify against Table 7.3.2 separately or use a double-angle/welded connection instead.
Final Thoughts
A rod brace where yield and fracture run within a few percent of each other is a genuine illustration of how close two seemingly different failure modes can sit once a specific material grade's fu/fy ratio is worked through the numbers.