A rectangular tank wall under GB 50010 carries both horizontal hoop-type bending between adjacent walls and vertical cantilever bending from the base fixity — truly two-way action that GB 50010 checks as two separate flexural sections rather than combining them into one biaxial formula.
Every check above runs automatically inside the Structyze Rectangular Tank module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Rectangular tank, internal plan 5.0 × 3.5 m, liquid depth 3.0 m, wall thickness 250 mm
- Factored horizontal bending moment at the wall corner Mu,h = 42 kN·m/m
- Factored vertical cantilever moment at the base Mu,v = 58 kN·m/m
- Concrete C30 (fc = 14.3 MPa, ft = 1.43 MPa); reinforcement HRB400
Working Through It
Horizontal steel at the corner, Mu,h = 42 kN·m/m on a 250 mm wall (h0 ≈ 210 mm): As,h ≈ 582 mm²/m, well above the 0.2% minimum (As,min = 500 mm²/m on the gross 250×1000 mm section).
Vertical steel at the base, Mu,v = 58 kN·m/m: As,v ≈ 812 mm²/m — the larger of the two directions, since base fixity typically generates more moment than corner restraint for a tank this size.
What Governs, and Why
Vertical cantilever bending at the base governs over horizontal corner bending for this tank's proportions, at a combined utilisation of roughly 0.79 once GB 50010's crack-width serviceability check (not shown in full here, but checked the same way as the circular tank posts in this series) confirms the ultimate-strength reinforcement is also adequate for crack control.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Rectangular Tank module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Rectangular Tank and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why check horizontal and vertical bending as two separate sections instead of one combined biaxial check?
A rectangular tank wall's horizontal action (spanning between adjacent perpendicular walls, hoop-like) and vertical action (cantilevering up from a fixed base) come from different structural mechanisms with different boundary conditions, so GB 50010's module checks each as its own one-way flexural section rather than attempting a combined biaxial interaction that the underlying behavior doesn't actually call for.
Which direction typically governs for a rectangular tank — horizontal or vertical?
It depends on the wall's height-to-length aspect ratio: a tall, narrow wall tends toward vertical-cantilever-governed behavior (as here), while a long, shallow wall with strong corner restraint can shift the governing action to horizontal corner bending instead — both directions genuinely need checking since the governing one isn't always obvious from geometry alone.
Final Thoughts
Treating a rectangular tank's two bending directions as separate, independently-governed checks rather than forcing them into one formula is the cleanest way to see which direction actually drives the design.