A bolted aluminium connection with a group of four fasteners, designed to Eurocode 9, needs a fastener group effect check that a single or double-bolt connection (like several other aluminium connection examples covered throughout this series) doesn't need to consider — long, loaded bolt groups don't necessarily share load equally across every fastener.

Every check above runs automatically inside the Structyze Aluminium Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Connection: 4 bolts in a single row (12 mm diameter, grade 8.8), connecting a 6 mm aluminium plate, alloy 6061-T6, spaced 60 mm c/c in the load direction
  • Design shear force: 38 kN

Working Through It

Individual bolt shear and bearing checks (treating each bolt as sharing load equally) both clear comfortably on their own, suggesting an apparently adequate utilization around 0.55.

Eurocode 9 requires a long-joint reduction factor for bolt groups where the distance between the first and last fastener in the load direction exceeds a defined limit relative to bolt diameter — for this group's total length of 180 mm (3 × 60 mm spacing) relative to the 12 mm bolt diameter, the long-joint check applies, since end bolts in a long row carry proportionally more load than interior bolts due to differential elastic elongation of the connected plates along the joint's length.

Applying Eurocode 9's long-joint reduction factor to the group's total nominal capacity gives an effective reduction of approximately 20%, bringing the real governing utilization to 0.55/0.80 ≈ 0.69.

What Governs, and Why

The long-joint reduction factor governs the connection's real effective capacity, pushing the utilization from an apparently comfortable 0.55 up to a tighter, but still adequate, 0.69 once correctly applied — a reminder that treating every bolt in a group as sharing load perfectly equally, without checking whether the group's length triggers this specific reduction, can meaningfully overstate a long bolted connection's real capacity.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Aluminium Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Aluminium Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why don't end bolts and interior bolts in a long bolted row share load equally?

As load transfers along a long bolted joint, the connected plates elastically elongate progressively along the joint's length, meaning the end fasteners (which see the full relative plate deformation accumulated along the joint) tend to pick up a disproportionately larger share of the total load than fasteners nearer the middle of a long row.

Is the long-joint effect significant for short connections with only 2 or 3 bolts?

Generally no — the effect becomes significant specifically as the total bolt group length grows relative to bolt diameter, which is why the shorter, 2-bolt connections discussed elsewhere in this series' aluminium connection content didn't need this particular check, while this longer, 4-bolt row does.

Final Thoughts

A bolted connection's real capacity isn't always just the sum of its individual bolts' capacities — a sufficiently long row of fasteners redistributes load unevenly along its length, and that's why Eurocode 9's long-joint reduction exists, and precisely why skipping it on a long bolt group risks overstating what the connection can actually deliver.

One thought on “How to Design an Aluminium Connection to Eurocode 9 (Step by Step, With Free Software)”

Leave a Reply