A purlin cleat connection under BS EN 1993 checks a actually signed reaction — wind uplift on a roof purlin reverses the usual downward gravity load into net upward force, and this module applies the identical three limit states regardless of which direction the force actually points.

Every check above runs automatically inside the Structyze Purlin/Girt Cleat Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Design reaction +15 kN (gravity, not uplift)
  • Cleat thickness 8 mm, depth 120 mm
  • Cleat material fy = 235 MPa, fu = 360 MPa
  • Bolt M12, Grade 4.6, edge distance 25 mm, pitch 45 mm
  • 2 bolts to purlin, 2 to support

Working Through It

Bearing geometry: αb = min(25/39, 400/360, 1.0) = 0.641; k1 = min(2.8(25/13)−1.7, 2.5) = 2.5. Bolt capacity: shear Fv,Rd ≈ 16.94 kN against bearing Fb,Rd ≈ 44.31 kN — shear governs.

Both bolt groups — cleat-to-purlin and cleat-to-support. Check against the identical 15 kN reaction: 2(16.94) = 33.88 kN capacity, utilisation 0.443 on each side.

The cleat plate's own shear yielding carries wide margin: Vc,Rd = 960(235/√3)/1.0/1000 ≈ 130.3 kN against the 15 kN demand.

What Governs, and Why

Both bolt groups govern equally at utilisation 0.443, well ahead of the cleat plate's own shear capacity at 0.115 — a light, minimum-practical connection for a comparatively small purlin reaction, typical of roof secondary framing.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Purlin/Girt Cleat Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Purlin/Girt Cleat Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does the connection check the same three limit states regardless of load direction?

The bolt shear, bolt bearing, and cleat shear-yielding formulas all depend only on the magnitude of the force being transferred, not its direction — a purlin cleat resisting 15 kN of uplift fails or passes the identical three checks as one resisting 15 kN of gravity load, just with the physical load path reversed through the connection.

What isn't checked in this simplified method?

Block tearing of the cleat plate around each bolt group (EC3's own term for what AISC calls block shear) isn't checked here — for a cleat with a small edge distance relative to the bolt diameter, that failure mode is important to verifying separately.

Final Thoughts

The signed-reaction convention is a small but truly important detail in every purlin cleat check across this series — a roof connection sized only for gravity load without checking the uplift case is a common and consequential oversight in light secondary framing.