This gusset plate's net-section fracture check runs at utilisation 0.928 at the software's own default inputs — the tightest check in this whole book's connection chapters, though it stays just under 1.0, unlike the identical geometry under Eurocode 3's lighter-strength material, which fails outright.
Every check above runs automatically inside the Structyze Truss Gusset Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Bolted connection, 3 members (chord + diagonal) at the joint
- Gusset 10 mm, fy = 300 MPa, fu = 440 MPa
- Bolt M20, Grade 8.8, fuf = 830 MPa
- Edge distance 35 mm, pitch 60 mm
- Member forces: top chord +150 kN, bottom chord −120 kN, diagonal +80 kN (4 bolts each)
Working Through It
Each member's own bolt group checks comfortably: governing capacity per bolt 97.0 kN, group capacity 388.0 kN — the top chord (150 kN) runs at utilisation 0.387, wide margin.
The governing member is the top chord. Net-section tension uses an effective width of 70 mm; after deducting the 22 mm bolt hole, net area is 480 mm². Yield capacity φNt ≈ 189.0 kN; fracture capacity φNtf ≈ 161.6 kN — fracture governs.
161.6 kN against the 150 kN demand gives utilisation 0.928 — the tightest check at this joint by a wide margin over block shear (0.190) and every bolt group.
What Governs, and Why
The gusset plate's own net-section fracture is the tightest check at the joint (utilisation 0.928) even though every bolt group and block shear both carry real margin. NZS 3404's combination of a lighter 0.85 fracture factor (versus Eurocode 3's γM2 = 1.25 divisor) and this default's higher-strength fu = 440 MPa plate keeps it just under 1.0 — truly tighter than the bolt groups, but not, at this code's own numbers, a failing one.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Truss Gusset Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Truss Gusset Plate Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why does the identical geometry pass under NZS 3404 but fail under Eurocode 3?
The combination of a lighter 0.85 fracture reduction factor and this example's higher-strength fu = 440 MPa plate under NZS 3404 keeps the net-section check just under 1.0, while EC3's γM2 = 1.25 divisor combined with a lower-strength S235 plate elsewhere in this series pushes the identical joint over 1.0 — a genuine, code-specific calibration and material-grade difference, not an inconsistency.
What would restore more comfortable margin on this joint?
Increasing the edge distance, increasing the gusset thickness, or moving to two bolt rows would each add real reserve — any change needs verifying against every other check, since a thicker or wider plate also shifts the block-shear areas.
Final Thoughts
Running the identical joint geometry across NZS 3404 and Eurocode 3 in this series shows exactly how close 'passes narrowly' and 'fails outright' can sit for a gusset plate — a few percentage points of fracture-factor calibration decides it.