A moment end-plate connection — the classic portal-frame knee or rafter splice — resists applied moment as a tension couple between the bolt group and the compression flange, but AISC's approach to combined bolt tension and shear is architecturally different from the quadratic interaction most other codes use, and it's easy to apply the wrong formula out of habit.

Every check above runs automatically inside the Structyze Moment End-Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Member 400 × 200 × 12 × 8 mm, Fy = 345 MPa
  • Factored moment 120 kN·m, shear 80 kN
  • End plate 32 mm, Fy = 345 MPa
  • 4 × M24 A325 bolts (tension zone), pitch 90 mm
  • Lever arm 360 mm, cantilever projection 50 mm

Working Through It

The tension-couple method converts the applied moment into bolt tension: T = Mu/Llever = 120,000/360 ≈ 333.3 kN total, shared equally among the 4 tension-zone bolts — 83.3 kN per bolt, with 20 kN of shear per bolt from the applied Vu.

Here's the AISC-specific step: rather than checking a (T/Tr)² + (V/Vr)² interaction ellipse the way IS 800 or CSA S16 would, AISC Ch J3.7 instead reduces the available tensile stress itself based on how much shear the bolt already carries. Here the shear demand is small enough that the reduced capacity Fntp caps right back at the full Fnt = 620 MPa — no actual reduction applies in this case.

The end plate itself, checked as a one-way cantilever strip spanning from the bolt line to the tension flange, needs a thickness of 24.4 mm against the 32 mm provided (utilisation 0.763) — the tightest check in the whole connection, tighter than either weld or the bolts themselves.

What Governs, and Why

End-plate bending governs at utilisation 0.763, well ahead of the bolt combined check (0.396), the flange weld (0.335) and the web weld (a comfortable 0.058). For a compact 4-bolt tension zone like this one, it's the plate's own bending stiffness — not the fasteners. That's usually the tightest link.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Moment End-Plate Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Moment End-Plate Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why doesn't shear reduce the bolt tension capacity here?

AISC's formula only reduces available tension capacity once the shear stress demand is large enough relative to the bolt's shear capacity — at only 44.2 MPa of shear stress against a much higher available shear stress, the reduced tension capacity calculation actually comes out above the unreduced Fnt, so the cap simply applies instead.

What about prying action?

This simplified method doesn't include a prying-force check, which can meaningfully increase bolt tension beyond the simple Tbolt value for a flexible end plate — keeping the plate reasonably stiff relative to the bolt gauge, or verifying against AISC Design Guide 4/16, covers that risk.

Final Thoughts

AISC's shear-reduces-tension-capacity approach to combined bolt loading is different from the interaction-ellipse method used elsewhere — important to double-checking which formula applies before reaching for a familiar one from a different code.

One thought on “How to Design a Moment End-Plate Connection to AISC 360 (Step by Step, With Free Software)”

Leave a Reply

Your email address will not be published. Required fields are marked *