Above roughly 20–25 ft of retained height, a plain cantilever stem gets uneconomically thick — a counterfort wall instead ties the stem to the heel with triangular webs at regular spacing, and the stem and heel then span horizontally between counterforts instead of vertically as a cantilever.

Every check above runs automatically inside the Structyze Counterfort Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Stem height 26 ft (8 m); stem 10 in, footing 24 in
  • Toe 5 ft, heel 13.75 ft
  • Counterforts 16 in thick at 10 ft spacing
  • Backfill γ = 115 pcf, φ = 30° (Ka = 0.33)
  • Allowable bearing 4.2 ksf, friction coefficient 0.5

Working Through It

Overall stability (overturning, sliding, bearing) uses the identical statics as a plain cantilever wall — here FSot = 4.3 and FSsl = 1.67 both clear their 1.5 limits with room to spare, and toe bearing runs at about 3.1 ksf against 4.2 ksf allowable.

The stem, though, is designed as a horizontal one-way slab spanning the 10 ft counterfort spacing — deliberately using the peak (base) earth pressure applied over the full height as a conservative simplification, rather than the true triangular pressure distribution. That gives a hogging moment of 14.5 kip·ft per foot at the counterfort, worked through to a required As of 0.44 in² against 0.62 in² provided.

Each counterfort itself is checked as a vertical cantilever T-beam carrying the full accumulated earth thrust down to the base — a moment of 1796 kip·ft, requiring 2.48 in² of steel against 6.32 in² provided (utilisation 0.39), with shear running much tighter at utilisation 0.84.

What Governs, and Why

Stem shear runs the tightest of any single check at utilisation 0.91 — a direct consequence of the deliberately conservative peak-pressure-over-full-height assumption used for the stem design. A real design would taper the stem steel (and reduce the design pressure) with height above the base, recovering meaningful margin that this simplified hand method doesn't capture.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Counterfort Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Counterfort Wall and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why do the stem and heel span horizontally here, not vertically?

The counterforts tie the stem to the heel at regular intervals, giving both a much shorter, stiffer span between counterforts than the full wall height — spanning horizontally between counterforts is far more efficient than cantilevering the full height as a plain wall would.

When does a counterfort wall make sense over a plain cantilever wall?

Once retained height climbs past roughly 20–25 ft, a plain cantilever stem needs to get so thick that the extra concrete and steel in triangular counterfort webs, spaced periodically, becomes the more economical choice.

Final Thoughts

A counterfort wall's horizontal-span mechanics for the stem and heel are the key structural difference from a plain cantilever wall — easy to get backwards if you're used to designing the simpler case.