Designing a steel beam to AISC 360 by hand means checking three separate flexural failure modes — full yielding, inelastic lateral-torsional buckling, and elastic lateral-torsional buckling — then verifying shear and deflection on top. Miss the unbraced-length check and the beam can look fine on paper while failing by buckling in the field.

Try it the fast way first: Structyze runs this exact AISC 360 procedure in your browser, free, with every intermediate value shown so you can check it against your own hand calculation. No download needed.

What This Guide Covers

We'll design a simply supported, laterally braced I-section beam from scratch to AISC 360: section properties, compactness classification, factored load, bending capacity, shear capacity, and the serviceability deflection check — with one worked example carried through every step.

The Example We'll Use

  • Span L = 6.0 m, unbraced length Lb = 0.5 m
  • Section 400 × 140 × 16 × 10 mm (depth × flange width × flange thickness × web thickness)
  • Material ASTM A992/A572 Grade 50, Fy = 345 MPa
  • Superimposed dead load 2 kN/m, live load 5 kN/m
  • Deflection limit L/360 (floor beam)

Step 1 — Section Properties

From the section dimensions: Ag ≈ 8160 mm², major-axis Iz ≈ 2.07×108 mm⁴, minor-axis Iy ≈ 7.35×10⁵ mm⁴, radius of gyration ry ≈ 30.0 mm, elastic section modulus Sx ≈ 1.03×10⁶ mm³, plastic section modulus Zx ≈ 1.20×10⁶ mm³. Self-weight works out to about 0.63 kN/m.

Step 2 — Section Classification (AISC 360 Table B4.1b)

Flange slenderness bf/2tf = 70/16 ≈ 4.38, well under the compact limit 0.38√(E/Fy) ≈ 9.15. Web slenderness h/tw = 368/10 = 36.8, under the compact limit 3.76√(E/Fy) ≈ 90.5. Both compact ⇒ the section is classified compact, meaning it can reach its full plastic moment before local buckling intervenes.

Step 3 — Factored Load and Design Actions

wu = 1.2(wself + wSIDL) + 1.6wLL = 1.2(0.63 + 2) + 1.6(5) ≈ 11.15 kN/m. For the 6 m simply supported span: Mu = wuL²/8 ≈ 50.2 kN·m and Vu = wuL/2 ≈ 33.5 kN.

Step 4 — Bending Capacity (AISC 360 Chapter F2)

Plastic moment capacity: Mp = ZxFy ≈ 413.6 kN·m. The limiting unbraced length for full yielding: Lp = 1.76ry√(E/Fy) ≈ 1272 mm. Since our actual Lb = 500 mm is well under Lp, lateral-torsional buckling doesn't govern at all — the beam reaches its full plastic capacity: φbMn = 0.9(413.6) ≈ 372.2 kN·m. Utilisation = 50.2/372.2 ≈ 0.135.

Step 5 — Shear Capacity (AISC 360 Chapter G2.1)

Web area Aw = D·tw = 400(10) = 4000 mm². φvVn = 1.0(0.6)(345)(4000) ≈ 828 kN, against a demand of only 33.5 kN — utilisation 0.040. Shear is almost never the governing check for a beam this lightly loaded relative to its depth.

Step 6 — Deflection Check (Serviceability)

Using service (unfactored) loads, wservice = 0.63 + 2 + 5 = 7.63 kN/m: δ = 5wserviceL⁴/(384EIz) ≈ 3.11 mm, against a limit of L/360 ≈ 16.67 mm — comfortably within limits (utilisation 0.187), and actually the tightest of the three checks even though it still passes easily.

Where Structyze Takes Over

Every step above — section classification, Lp versus Lb, bending, shear, deflection. Runs automatically inside the Structyze Steel Beam module, free to try online, with the governing AISC 360 clause shown against every result.

The free trial covers a curated set of modules. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Frequently Asked Questions

What happens if the unbraced length is longer?

As Lb grows past Lp, the beam enters inelastic lateral-torsional buckling, and capacity drops linearly between Mp and a lower buckling moment. Past a second limit, Lr, it becomes fully elastic LTB with capacity dropping further. This is how closely spaced deck fasteners or purlin cleats matter — they shorten Lb and keep the beam in the full-yielding regime.

Does this check cover end connections?

No — this module checks the member itself. Bolted or welded end connections (shear tabs, clip angles) are a separate check against AISC 360 Chapter J.

What about continuous spans or point loads?

This worked example uses a single UDL on a simply supported span. Continuous spans, cantilevers and point loads need their own moment/shear diagrams before the same capacity checks apply.

Final Thoughts

Checking a steel beam by hand against AISC 360 is useful to doing once to understand the three failure modes — but for a full framing plan with dozens of beams at different spans and bracing, it doesn’t scale. Try Structyze free in your browser and get the same clause-by-clause check, instantly, for every beam on your project.

One thought on “How to Design a Steel Beam to AISC 360 (Step by Step, With Free Software)”

Leave a Reply

Your email address will not be published. Required fields are marked *