NBR 6118 checks each rib of a ribbed (joist) slab as its own small T-beam, with the topping slab acting as the compression flange — mechanically the identical idea this series already used for the counterfort wall's T-beam counterfort, just at joist scale rather than wall scale.

Every check above runs automatically inside the Structyze Ribbed Slab module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Ribbed slab, rib spacing 600 mm, rib width 120 mm, overall depth 280 mm, topping 50 mm
  • Rib span 5.5 m (simply supported), factored moment per rib Md = 18.5 kN·m
  • Concrete C25 (fcd = 17.86 MPa); reinforcement CA-50 (fyd = 434.8 MPa)
  • Effective flange width limited to the rib spacing, 600 mm

Working Through It

Treating the rib as a T-beam with a 600 mm wide, 50 mm deep flange: required tension steel As ≈ 215 mm² per rib, with the neutral axis staying within the flange depth (x ≈ 18.4 mm < 50 mm) — true T-beam action, the compression block never dips into the narrower rib web at all.

With x comfortably inside the flange, the section behaves specifically like a rectangular beam of the full 600 mm flange width for this particular moment — the rib's narrow 120 mm web only matters for shear, not for this flexural check.

What Governs, and Why

Flexure reaches utilisation 0.71 with the neutral axis safely inside the flange — the practical takeaway for any ribbed slab is that moment capacity is almost always generous as long as the topping is in compression, while shear at the narrow rib web, not flexure, is where a ribbed slab's real design tightness tends to show up.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Ribbed Slab module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Ribbed Slab and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does keeping the neutral axis inside the flange matter here?

As long as x stays within the topping depth, the full flange width (600 mm) is available in compression and the section behaves as a wide, generous rectangular beam; if x pushed down into the narrow 120 mm rib web instead, the compression area would shrink sharply and the T-beam formulas would need to switch to accounting for that narrower web explicitly.

Why is shear typically the tighter check on a ribbed slab rather than flexure?

The rib's web is narrow by design, often just 100–150 mm, which gives it comparatively little shear area to work with even though the wide flange gives it generous flexural capacity — this mismatch between a wide compression flange and a narrow shear-resisting web is the defining structural tension in every ribbed-slab design.

Final Thoughts

A ribbed slab's rib is a small T-beam in every structural sense that matters — checking it that way, rather than as a plain rectangular section, is what correctly credits the topping's real contribution.