A counterfort retaining wall's stem spans horizontally between counterforts rather than cantilevering vertically from the base the way a plain cantilever wall does — NBR 6118 checks the stem as a continuous slab spanning between supports, while the counterfort itself gets checked as a cantilevered T-beam with the stem acting as its flange.
Every check above runs automatically inside the Structyze Counterfort Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Counterfort wall, retained height 7.0 m, counterfort spacing 3.0 m
- Stem thickness 300 mm, horizontal design moment at the counterfort face Md,stem = 95 kN·m/m
- Counterfort (T-beam) design moment at its base Md,cf = 980 kN·m
- Concrete C30 (fcd = 21.4 MPa); reinforcement CA-50
Working Through It
Stem, spanning horizontally between counterforts: As ≈ 820 mm²/m at Md,stem = 95 kN·m/m, x/d ≈ 0.097 — lightly stressed, well inside Domain 3.
Counterfort T-beam, with the 300 mm stem acting as its compression flange over an effective flange width limited by counterfort spacing: required tension steel at the counterfort base As ≈ 4,850 mm², utilisation 0.84 against the governing Md,cf — the dominant structural element in the whole wall.
What Governs, and Why
The counterfort itself, not the stem, is where this wall's real structural demand concentrates — the stem's job is simply to collect earth pressure and span it sideways into the counterforts, which then do the heavy lifting of carrying that load down as cantilevered T-beams fixed at the base.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Counterfort Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Counterfort Wall and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why does the stem span horizontally here instead of cantilevering vertically like a plain cantilever wall?
Adding counterforts at regular intervals gives the stem vertical support lines to span between, which is far more efficient in bending than a tall, unsupported vertical cantilever — it's precisely this horizontal-spanning stem, support by counterforts, that makes the counterfort wall type worthwhile at retained heights beyond roughly 6 metres.
Why does the counterfort get checked as a T-beam rather than a plain rectangular cantilever?
The stem, being cast monolithically with the counterfort and sitting in the compression zone over part of its depth, acts as a genuine compression flange specifically like a floor slab does for a T-beam floor girder — ignoring that flange contribution would understate the counterfort's real capacity.
Final Thoughts
A counterfort wall is really two structural systems working together — a lightly-loaded spanning stem and a heavily-loaded cantilevered T-beam counterfort — and NBR 6118's general flexure provisions handle both once each member's actual support condition is identified correctly.