NBR 6118 treats a cantilever retaining wall's vertical stem as an ordinary cantilever flexural member once the geotechnical overturning and sliding checks are satisfied — the code's own strain-domain classification applies here as it did for the combined footing checked elsewhere in this series, just at a much lower reinforcement ratio.
Every check above runs automatically inside the Structyze Cantilever Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Cantilever retaining wall, retained height 4.0 m, stem base thickness 350 mm (d ≈ 300 mm)
- Active lateral earth pressure (factored) giving a stem base moment Md = 145 kN·m/m
- Concrete C25 (fcd = 17.86 MPa); reinforcement CA-50 (fyd = 434.8 MPa)
- Base width (toe + heel) 2.8 m, founded on medium-dense sand
Working Through It
Stem base reinforcement at Md = 145 kN·m/m: As ≈ 1,185 mm²/m, giving x/d ≈ 0.134 — well inside Domain 3's ductile range and comfortably clear of the over-reinforced boundary.
Sliding and overturning stability (checked as separate geotechnical limit states, not flexural ones) both pass with factors of safety above 1.5, which is the real precondition for the stem flexure check above to be meaningful at all — a wall that slides or overturns never gets the chance to fail in bending.
What Governs, and Why
Stem flexure reaches utilisation 0.76 at the base, the governing structural check once overturning and sliding are both confirmed adequate — the familiar two-tier verification (geotechnical stability first, then structural section design) this series applies to every retaining-wall code.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Cantilever Wall module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Cantilever Wall and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why check geotechnical stability before the stem's own flexural capacity?
A structurally adequate stem is irrelevant if the whole wall overturns or slides as a rigid body — geotechnical stability (overturning about the toe, sliding along the base) governs whether the wall stands at all, and only once those checks pass does the stem's internal bending become the question that actually matters.
Why is the stem's reinforcement ratio so much lower here than in the combined footing elsewhere in this series?
A cantilever stem's moment arises from lateral earth pressure building up gradually with depth, producing a comparatively modest base moment relative to the stem's own thickness, while the combined footing carries concentrated column loads directly — different load origins naturally land at very different reinforcement demands even under the identical NBR 6118 flexural method.
Final Thoughts
A cantilever wall's stem check is really the second half of a two-part verification — NBR 6118 only gets to say anything meaningful about it once the wall has already proven it won't slide or overturn as a whole.