A sawn hardwood timber floor beam designed to Brazil's NBR 7190 checks shear using a different reference plane than several other timber codes covered throughout this series — rolling shear along the grain rather than the simpler transverse shear check that sometimes gets conflated with it.
Every check above runs automatically inside the Structyze Timber Beam module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Beam: Dicotyledon hardwood, strength class C30, 120 mm × 300 mm, span 4.0 m, simply supported
- Characteristic shear strength parallel to grain, f_v0k: 4.0 MPa
- Design shear force: 8.2 kN
- k_mod: 0.7, γ_wv (shear partial factor): 1.8
Working Through It
Design shear strength: f_v0d = k_mod × f_v0k / γ_wv = 0.7 × 4.0 / 1.8 = 1.56 MPa.
Actual shear stress (rectangular section, maximum at neutral axis): τ = 1.5 × V / A = 1.5 × 8200 / (120 × 300) = 0.342 MPa.
Utilization: 0.342/1.56 = 0.22.
Bending and deflection checks are run alongside, with deflection governing overall at utilization 0.51, consistent with the general timber deflection-sensitivity pattern discussed throughout this series.
What Governs, and Why
Deflection governs at utilization 0.51, with shear clearing very comfortably — another confirmation of the pattern seen repeatedly across this series' timber beam content: for ordinary floor spans, stiffness (deflection), not strength (bending or shear), is almost always the binding constraint, regardless of which national code or species is involved.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Timber Beam module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Timber Beam and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why is shear parallel to grain checked differently from shear perpendicular to grain in timber design?
Timber's fibrous structure makes it considerably weaker in shear along the grain direction (where fibres can separate from each other) than across it, which is why parallel-to-grain shear strength is always the explicitly governing, lower value checked in ordinary beam design, rather than a generic, direction-independent shear strength.
Does NBR 7190's γ_wv partial factor for shear differ from its compression or bending partial factors?
Yes — NBR 7190 assigns different partial factors to different failure modes, reflecting that timber's reliability and variability differ by stress type, similar in spirit to how other codes discussed throughout this series apply different safety margins to different checks rather than one blanket factor.
Final Thoughts
Yet another timber beam example throughout this series where deflection, not the strength checks that usually get the most calculation attention, turns out to be the real governing number — a consistent enough pattern across species, countries, and code philosophies that it's worth treating as close to a default expectation for ordinary timber floor spans.