A post-tensioned beam designed to IS 1343 includes a check that's easy to overlook entirely if you're focused only on mid-span bending — the anchorage (end block) bursting stress check, which addresses the intense, locally concentrated stress where the tendon's prestress force transfers from a small anchorage plate into the full width of the concrete section.

Every check above runs automatically inside the Structyze Prestressed Concrete Beam module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Beam: 350 mm × 700 mm, post-tensioned with 2 tendons anchored at the end face, each tendon's jacking force: 980 kN
  • End block length (per IS 1343, taken as equal to the section's overall depth): 700 mm
  • f_ck: 40 MPa

Working Through It

At the anchorage, each tendon's concentrated force spreads out from the anchor plate into the full section width over the end block length — this spreading generates transverse tensile (bursting) stress within the end block, perpendicular to the tendon's own direction, which is a fundamentally different stress state from the ordinary flexural bending stress calculated at mid-span.

Bursting tensile force is calculated using IS 1343's design charts (based on the ratio of anchor plate size to section depth) — for this anchorage geometry, the bursting force works out to approximately 0.22 × the tendon's jacking force per anchor, giving 216 kN per tendon.

Transverse reinforcement (closely spaced stirrups/links within the end block zone) is sized to resist this bursting force in tension: required area = bursting force / permissible steel stress = 216,000 / 200 = 1,080 mm², provided here as 10 mm links at 75 mm spacing within the end block, giving 1,130 mm² — a utilization of 216/226 × (reinforcement capacity ratio) ≈ 0.96, a truly tight check.

The mid-span ultimate flexural check, by contrast, clears comfortably at utilization 0.74 — the end block check, not the familiar mid-span bending check, is this beam's tightest margin.

What Governs, and Why

The anchorage bursting stress check governs at a tight utilization of approximately 0.96, well ahead of the mid-span flexural check at 0.74 — a check that's entirely absent from ordinary RCC beam design and easy to underestimate in prestressed design specifically because it has nothing to do with the beam's overall span behavior at all; it's a purely local, anchorage-zone phenomenon unique to how prestress force is introduced into the concrete.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Prestressed Concrete Beam module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Prestressed Concrete Beam and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why is bursting stress a concern only near the anchorage, not along the rest of the beam?

Because it's caused by the transition from the tendon's highly concentrated force at the anchor plate spreading out to act over the section's full width — once that spreading is complete (within roughly one section depth from the anchor, per St. Venant's principle), the stress distribution becomes the ordinary, more uniform flexural stress pattern seen along the rest of the span.

Does a larger anchor plate reduce the bursting stress?

Yes — a larger anchor plate relative to the section size spreads the force over a shorter transition zone with less stress concentration, directly reducing the calculated bursting force and the transverse reinforcement needed to resist it.

Final Thoughts

A prestressed beam's hardest check isn't always somewhere along its span at all — the anchorage zone's bursting stress is a actually separate, local phenomenon that mid-span flexural design has no mechanism to catch. That's why it needs its own explicit calculation rather than being assumed to be covered by an otherwise comfortable overall design margin.