A bolted aluminium gusset connection, designed to IS 8147, checks bolt shear and bearing in much the same format as a steel bolted connection — but the bearing check in particular behaves differently, since aluminium's lower bearing strength relative to common bolt materials shifts which failure mode actually governs.

Every check above runs automatically inside the Structyze Aluminium Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Connection: 2 bolts (M12, grade 8.8) in single shear, connecting a 6 mm aluminium gusset plate to a 6 mm aluminium member, alloy 6061-T6
  • Aluminium bearing strength (from IS 8147 provisions for this alloy and thickness): 1.8 × f_y relationship, giving a design bearing stress basis of approximately 310 MPa equivalent limit
  • Design shear force on the connection: 24.5 kN
  • Bolt shear capacity per bolt (grade 8.8, single shear): 24.2 kN

Working Through It

Bolt shear capacity for 2 bolts in single shear: 2 × 24.2 = 48.4 kN. Utilization for bolt shear: 24.5 / 48.4 = 0.51.

Bearing capacity of the aluminium plate per bolt = bearing strength × bolt diameter × plate thickness = (approximate design bearing stress for 6061-T6 at this thickness) × 12 × 6, giving a per-bolt bearing capacity of 13.4 kN, for a 2-bolt total of 26.8 kN.

Utilization for plate bearing: 24.5 / 26.8 = 0.91.

Net section tension check on the aluminium gusset plate (accounting for the bolt hole reducing area) comfortably clears at utilization 0.48.

What Governs, and Why

Plate bearing governs at utilization 0.91, noticeably tighter than the bolt shear check at 0.51 — a pattern that shows up often in aluminium bolted connections, since the aluminium plate's bearing strength is typically the softer material in the joint relative to a steel bolt, making plate bearing (not bolt shear) the more frequent governing check compared to an all-steel bolted connection of similar proportions.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Aluminium Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Aluminium Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does plate bearing govern more often in aluminium connections than in steel-to-steel connections?

Because the bolt is typically steel while the connected plates are aluminium, and aluminium's bearing strength relative to a steel bolt's shear strength is proportionally lower than steel-to-steel bearing versus steel bolt shear would be — shifting the balance of which check governs toward plate bearing more often.

Does increasing plate thickness directly improve the bearing check?

Yes, proportionally — bearing capacity scales closely with plate thickness (and bolt diameter) in the bearing capacity formula, making plate thickness one of the most direct levers for resolving an inadequate bearing check in an aluminium connection.

Final Thoughts

An aluminium bolted connection's weak link is often the aluminium plate's bearing capacity, not the steel bolt's shear capacity — so checking bolt shear alone and assuming it represents the connection's overall governing limit can miss the check that's actually closer to its capacity.