NZS 3404 deliberately uses a lower capacity factor for a connection (φ = 0.80) than for a member limit state (φ = 0.90) — the code's own explicit view that a connection failure is generally more brittle and less ductile than a member failure, and therefore deserves less credit.
Every check above runs automatically inside the Structyze Bolted / Welded Connection module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.
The Example We'll Use
- Bolted, bearing-type connection, factored shear 150 kN
- Bolt M20, AS/NZS 1252 Grade 8.8, fuf = 830 MPa
- 4 bolts, connected plate 10 mm, fup = 440 MPa
Working Through It
Bolt shear: Ac = 0.75 × gross shank area = 235.6 mm² (threads intercepted, the standard conservative case); φVf = 0.8(0.62)(830)(235.6)/1000 ≈ 97.0 kN.
Bolt bearing: φVb = 0.8(3.2)(20)(10)(440)/1000 ≈ 225.3 kN — shear governs decisively at 97.0 kN per bolt. Group capacity = 4(97.0) = 388.0 kN.
What Governs, and Why
The bolt group passes comfortably at utilisation 0.387 — bolt shear governs narrowly over bearing, typical for a high-strength Grade 8.8 bolt against a moderate-thickness ply. Worth noting explicitly: unlike CSA S16 and AISC 360, which both apply a directional-strength-increase factor for a weld loaded transverse to its axis, NZS 3404's fillet weld provisions use the same nominal capacity regardless of load angle — more conservative for a transverse weld, but really simpler to apply, since no loading-angle input is needed at all.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Bolted / Welded Connection module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.
The free trial covers a curated set of flagship modules including this one. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why does NZS 3404 penalize connections more than members?
The code's own view, reflected directly in its capacity factors, is that a connection failure — a bolt shearing, a weld fracturing — tends to be more sudden and less ductile than a member reaching its capacity through yielding, which typically gives visible warning first. The lower φ = 0.80 for connections versus φ = 0.90 for members builds that extra margin in explicitly.
What's the practical consequence of NZS 3404's angle-independent weld strength?
For a weld loaded transverse to its axis, codes with a directional-strength-increase factor (like CSA S16 and AISC 360) credit extra capacity that NZS 3404 doesn't — meaning a transverse weld designed to NZS 3404 will come out more conservative (thicker or longer) than the identical geometry checked under a code that credits the directional effect.
Final Thoughts
NZS 3404's explicitly lower connection capacity factor is a clean, code-stated acknowledgment that connections and members don't deserve the same safety margin — worth remembering when comparing utilisation numbers across a design that mixes both.