NZS 3404 applies one shared Section/Fabrication Category to both the chord and the diagonal of a truss, just as AS 4100 does — a real simplification important to naming explicitly, since a mixed truss with rolled chords and cold-formed diagonals would need two separate αb values, not the single shared selection this module offers.

Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Span 16 m, depth 1.6 m, 8 panels
  • Panel point load (service) 20 kN
  • Chord: area 2500 mm², r = 35 mm, effective length 2 m
  • Diagonal: area 2200 mm², r = 28 mm, effective length 2.5 m
  • Section/fabrication category: hot-rolled, αb = 0
  • Material AS/NZS 3679.1 Grade 300, fy = 300 MPa

Working Through It

Factored UDL w* = 1.35(10) = 13.5 kN/m, giving global M* = 432 kN·m and V* = 108 kN. Chord force = 270 kN; diagonal force ≈ 172.9 kN.

Bottom chord tension: φNt = 0.9(2500)(300)/1000 = 675.0 kN (utilisation 0.400). Both compression members run through the identical λn/αa/αc chain — the top chord (le/r = 57.1) gives αc = 0.793, φNc ≈ 535.4 kN; the diagonal (le/r = 89.3) gives αc = 0.556, φNc ≈ 330.2 kN.

What Governs, and Why

Diagonal compression governs narrowly at utilisation 0.524 over the top chord's 0.504 — both comfortably ahead of the tension chord's 0.400, the identical numbers this series finds for AS 4100 on the same geometry, since NZS 3404's member-capacity formula set is drawn from the same joint AS/NZS development as AS 4100.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Steel Truss and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

What would a genuinely mixed-fabrication truss need that this module doesn't offer?

A real truss with rolled chords and cold-formed hollow-section diagonals would need the chord checked with αb = 0 (hot-rolled) and the diagonal checked separately with αb = −0.5 (cold-formed, Table 6.3.3's more favourable value) — two different buckling chains for the two member types, not the single shared category this module applies to both.

Why do NZS 3404 and AS 4100 give identical numbers here?

Both standards share a common development history under the Australia/New Zealand joint standards framework, and the member capacity formulas — including this exact λn/αa/αc buckling chain — are essentially identical between the two, even though each retains its own clause numbering and some national-specific provisions elsewhere.

Final Thoughts

Seeing NZS 3404 reproduce AS 4100's truss numbers precisely is a useful confirmation of how closely the two standards' core member-design provisions track each other, even while each keeps its own distinct clause references.

Leave a Reply

Your email address will not be published. Required fields are marked *