The UK National Annex to Eurocode 3 applies the identical Ayrton-Perry buckling curve to a truss chord and diagonal as the CEN base version — only the buckling curve selection (by section shape and axis) and each member's own slenderness truly differ, not the underlying formula itself.
Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Span 16 m, depth 1.6 m, 8 panels
- Panel point load (service) 20 kN
- Chord: area 2500 mm², i = 35 mm, buckling length 2 m
- Diagonal: area 2200 mm², i = 28 mm, buckling length 2.5 m
- Buckling curve c; material S235, fy = 235 MPa
Working Through It
With the UK NA's variable-action factor of 1.5 (matching the CEN base, not AISC's 1.6), the equivalent factored UDL is 15 kN/m, giving MEd = 480 kN·m and VEd = 120 kN. Chord force = 300 kN; diagonal force ≈ 192.1 kN.
Bottom chord tension: Npl,Rd = 2500(235)/1.0/1000 ≈ 587.5 kN (utilisation 0.511). Both compression members use buckling curve c (αimp = 0.49, typical for an angle-section diagonal) — the top chord (λ̄ = 0.608) gives χ = 0.780, Nb,Rd ≈ 458.5 kN; the diagonal (λ̄ = 0.951, notably higher) gives χ = 0.569, Nb,Rd ≈ 294.1 kN.
What Governs, and Why
Top chord and diagonal compression run almost identically at utilisation 0.654 and 0.653 despite very different slenderness ratios (57.1 vs 89.3) — the diagonal's smaller area and larger imperfection-driven reduction happen to roughly offset its lighter force, a coincidence of this particular geometry rather than a general rule. Both comfortably clear the tension chord's 0.511, identical to the CEN base version of this same truss elsewhere in this series, since buckling curve selection and member design follow the same EN 1993-1-1 core provisions regardless of which National Annex applies.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Steel Truss and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
If the UK NA and CEN base give identical truss results, why does the National Annex matter at all?
For member buckling checks like this one, the UK NA and CEN base values often coincide closely or, since γM1 (the partial factor for buckling resistance) is commonly set to 1.0 in both — the Annexes diverge more meaningfully for checks like concrete's αcc factor (as this series' RCC beam and column comparisons show) than for steel member buckling, where the underlying Eurocode 3 provisions are more uniformly adopted.
Why does a truss diagonal typically use curve c rather than curve a or b?
A truss diagonal is very often an angle section, for which curve b or c is the typical Table 6.2 assignment (this book defaults to c); the same member modelled instead as a rolled I-section buckling about its major axis would use curve a or b instead, materially changing αimp and therefore its capacity at the identical slenderness.
Final Thoughts
Seeing a UK National Annex truss check land on the identical numbers as its CEN base counterpart is a useful confirmation that not every Eurocode 3 National Annex choice moves the needle equally across every check type.