CSA S16 has no dedicated clause for combining biaxial bending with no axial term the way a gantry girder needs — so this module applies the same simplified linear-interaction philosophy CSA uses for its beam-column check, just with the axial term dropped entirely.

Every check above runs automatically inside the Structyze Gantry Girder module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Span 6 m
  • Section 450 × 200 × 20 × 12 mm
  • Maximum static wheel load 100 kN
  • Vertical impact factor 25%, lateral surge 10% of wheel load
  • Material CSA G40.21 350W, Fy = 350 MPa

Working Through It

Section classification finds both flange (5.0 against a Class 1 limit of 7.75) and web (34.2 against 58.80) comfortably Class 1. Factored wheel load Wf = 1.5(100)(1.25) = 187.5 kN; factored surge Sf = 1.5(100)(0.10) = 15.0 kN.

Design moments: Mfx = 187.5(6)/4 = 281.25 kN·m (major axis), Mfy = 15.0(6)/4 = 22.50 kN·m (minor axis). Moment resistances: Mrx ≈ 700.65 kN·m, Mry ≈ 130.65 kN·m.

What Governs, and Why

The by-analogy biaxial check governs at utilisation 0.574 (281.25/700.65 + 22.50/130.65 = 0.401 + 0.172) — the vertical wheel-load term dominates over the lateral surge term, a typical split for a moderate 10% surge allowance. Shear carries wide margin at utilisation 0.167.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Gantry Girder module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Gantry Girder and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why apply a beam-column interaction formula when there's no axial load?

CSA S16 doesn't publish a standalone biaxial-bending-only interaction the way some codes provide for a beam-column check — the closest codified analogy is the beam-column combined-loading philosophy with the axial term simply set to zero, which is mechanically equivalent to a pure biaxial-bending interaction check anyway.

Does this account for the girder's compression flange buckling under combined loading?

No — this module checks section moment capacity in each axis independently but doesn't model lateral-torsional buckling of the top flange under the combined vertical-plus-lateral loading, nor fatigue under repeated crane duty cycles. Both need separate verification for a girder in regular service.

Final Thoughts

Borrowing a beam-column interaction formula for a pure biaxial-bending problem, just by zeroing out the axial term, is a clean example of reusing an existing codified method rather than inventing a new one for a gap in the code's own coverage.

Leave a Reply

Your email address will not be published. Required fields are marked *