A bunker's bearing check rests the full weight of stored material directly on the base slab, deliberately ignoring the wall friction that Janssen's own theory says carries part of that load into the walls — a conservative simplification that can genuinely push the bearing check right up to its allowable limit.
Every check above runs automatically inside the Structyze Bunker module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Internal 8 × 6 m, height 6 m
- Wall 300 mm, base 350 mm, cover 40 mm
- Stored material: γ = 18 kN/m³, φ = 35°, wall friction μ′ = 0.4
- Allowable bearing 150 kN/m²; concrete C30/37, steel B500
Working Through It
The rectangular hydraulic radius R = LW/[2(L+W)] ≈ 1.714 m feeds Janssen's equation (the same theory a circular silo uses) to give a base horizontal pressure ph ≈ 6.6 kN/m² — applied uniformly over the full wall height, conservative for the upper portions where the true Janssen curve would actually be lower.
Each wall, designed as an independent one-way vertical cantilever, sees MEd = 1.5(6.6)(6)²/2 ≈ 178 kN·m/m, requiring 1776 mm²/m against the 2094 mm²/m provided (utilisation 0.85). One-way shear clears comfortably at utilisation 0.32.
Base bearing tells a different story: with the engine resting the full stored-material column on the base (wall friction ignored entirely for this check), q = 7068/48 ≈ 147 kN/m² against 150 kN/m² allowable — utilisation 0.98, right at the edge.
What Governs, and Why
Base bearing runs right at the limit (utilisation 0.98) precisely because the engine deliberately ignores Janssen wall friction for this specific check, resting the full material column on the base slab as a conservative simplification. Wall strength itself is comfortable throughout; any deeper fill or lower allowable bearing would push this specific check over — widening the base slab beyond the wall footprint, or crediting wall friction per EN 1991-4, are the two ways to recover margin.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze Bunker module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For Bunker and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why would the bearing check ignore the same wall friction that the pressure calculation relies on?
It's a deliberately conservative simplification: crediting wall friction would reduce the base bearing demand (since some of the material's weight would be carried by the walls instead), but the base slab and its supporting soil need to be sized for the worst case, and assuming zero friction relief is the safer assumption for that specific check even though the lateral pressure calculation elsewhere does credit it.
What's the practical fix if bearing runs over the limit?
Widening the base slab beyond the wall footprint spreads the same total weight over more area, directly reducing the bearing pressure — a more targeted fix than thickening the walls, since the walls themselves aren't what's driving this particular check.
Final Thoughts
A bunker's bearing check running right at its limit, while every structural wall check has real margin, is a textbook case of result that's easy to miss if you only skim the wall design and assume the foundation is automatically fine.