A cold-formed steel connection fails in ways a thick hot-rolled plate never would — a thin sheet bearing against a comparatively rigid fastener can fail by tilting and pull-through well below the plain-bearing capacity a simple D×t×Fu formula would predict, and that's why this module applies a deliberate 0.5× reduction as a conservative stand-in.
Every check above runs automatically inside the Structyze CFS Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Fastener M10, sheet thickness 2 mm
- Number of fasteners 4
- Ultimate strength Fu = 450 MPa
- Factored load on joint 6 kN
Working Through It
The per-fastener capacity formula, φRn = 0.5Dt Fuφ with φ = 0.65, deliberately halves what a plain-bearing calculation (D×t×Fu alone) would give — a disclosed, simplified stand-in for the full AISI S100 Chapter E fastener family, which actually contains several distinct failure modes (bearing, bolt tilting, pull-out, pull-over, net-section fracture) that a thin sheet can fail through.
φRn = 0.5(10)(2)(450)(0.65)/1000 ≈ 2.925 kN per fastener. With 4 fasteners sharing the load equally, joint capacity = 4(2.925) ≈ 11.70 kN against the 6 kN demand — utilisation 0.513, roughly the middle of a comfortable range.
What Governs, and Why
The joint passes at utilisation 0.513 — a modest margin for a light 4-fastener connection, appropriate for a preliminary sizing check rather than a finalized design. The 0.5× reduction baked into this simplified formula is explicitly disclosed as conservative, not as a substitute for the full multi-mode fastener check a final design needs.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze CFS Connection module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For CFS Connection and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why can't a thin CFS sheet just use the same bearing formula as a thick plate?
A thick plate bearing against a bolt fails in a relatively simple, well-understood plain-bearing mode; a thin sheet bearing against the same fastener can instead tilt and progressively pull through the hole at a load well below the plain-bearing prediction, especially for a thin sheet paired with a larger-diameter fastener — a different failure mechanics that the simple D×t×Fu formula doesn't capture on its own.
What should a final design check that this simplified method skips?
The full AISI S100 Chapter E fastener family — bearing, tilting, pull-out, pull-over, and net-section fracture of the connected sheet. Along with minimum edge distance and fastener spacing requirements, none of which are verified by this preliminary bearing-mode check alone.
Final Thoughts
The 0.5× bearing reduction in this CFS connection check is a deliberately conservative placeholder, not a real AISI S100 equation — useful for an early sizing pass, but a final connection design needs the full fastener-mode family checked explicitly.