AS 4100 applies a single Section/Fabrication Category selection to both the chord and the diagonal of a truss — a real simplification important to noticing, since a genuinely mixed truss with rolled chords and cold-formed hollow diagonals would need two different category values, not one shared selection.

Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Span 16 m, depth 1.6 m, 8 panels
  • Panel point load (service) 20 kN
  • Chord: area 2500 mm², r = 35 mm, effective length 2 m
  • Diagonal: area 2200 mm², r = 28 mm, effective length 2.5 m
  • Section/fabrication category: hot-rolled, αb = 0
  • Material AS/NZS 3679.1 Grade 300, fy = 300 MPa

Working Through It

Factored UDL w* = 1.35(10) = 13.5 kN/m, giving global M* = 432 kN·m and V* = 108 kN. Chord force = 432/1.6 = 270 kN; diagonal force = 108/sin(38.66°) ≈ 172.9 kN.

Bottom chord tension: φNt = 0.9(2500)(300)/1000 = 675.0 kN (utilisation 0.400). Both compression members run through the λn/αa/αc chain: the top chord (le/r = 57.1) gives αc = 0.793 and φNc ≈ 535.4 kN; the diagonal (le/r = 89.3) gives a lower αc = 0.556 and φNc ≈ 330.2 kN.

What Governs, and Why

Diagonal compression governs narrowly at utilisation 0.524, just ahead of the top chord's 0.504 — both comfortably ahead of the tension chord's 0.400. This is the same pattern seen consistently across codes for a truss with this modest depth-to-span ratio: the diagonal's steeper slenderness narrows its margin fastest.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Steel Truss and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

What would change for a mixed rolled-and-hollow-section truss?

Each member type carries its own Section/Fabrication Category (and corresponding αb value) under AS 4100's Table 6.3.3(1) — a cold-formed hollow-section diagonal paired with rolled chords would need its compression check run with a different αb, not the shared hot-rolled value used throughout this simplified single-category model.

Why is the panel-point load factored at 1.35 here?

This book treats the panel-point load as dead-load-dominated (AS/NZS 1170.0's 1.35G combination) — a live-load-dominated truss loading would need the corresponding 1.2G+1.5Q combination factored in instead, which would change the governing UDL and every downstream force.

Final Thoughts

AS 4100's single shared fabrication category is a convenient simplification for a uniform truss, but it's important to remembering it stops being accurate the moment the chord and diagonal are really different member types.

One thought on “How to Design a Steel Truss to AS 4100 (Step by Step, With Free Software)”

Leave a Reply

Your email address will not be published. Required fields are marked *