A UK National Annex column check builds a full N–M interaction diagram from strain compatibility with the parabola-rectangle stress block — but the slenderness check at the end is what actually decides whether the interaction result even applies as calculated.

Every check above runs automatically inside the Structyze RCC Column module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The Example We'll Use

  • 400 × 400 mm, effective length 3 m (braced)
  • Cover 35 mm (XC1); links φ8
  • Axial: permanent 800 kN, variable 400 kN
  • Moment: permanent 20 kN·m, variable 15 kN·m
  • Concrete C25/30, steel B500; 8φ20, links at 200 mm

Working Through It

Design actions: NEd = 1.35(800)+1.5(400) = 1680 kN, MEd = 1.35(20)+1.5(15) = 49.5 kN·m. The squash load, using the UK NA's αcc = 0.85 (fcd = 14.17 MPa), comes to NRd,max ≈ 3324 kN — utilisation 0.51.

Sweeping the neutral-axis depth to build the N–M interaction envelope gives MRd ≈ 165 kN·m at NEd = 1680 kN, so MEd/MRd = 0.30 — comfortable on its own.

But the slenderness check tells a different story: λ = ℓ0/i = 3000/115.5 = 26.0 against a limit λlim = 10.78/√n = 12.5 (using n = NEd/(Acfcd) = 0.74) — more than double the limit. The column is slender, and second-order effects can't be ignored.

What Governs, and Why

Slenderness fails outright at more than twice the limit (utilisation 2.08) even though both the squash load (0.51) and the N–M interaction (0.30) pass comfortably. Second-order moments — typically adding roughly 30–60% to MEd via the nominal-curvature method. Must be included before the interaction check can be trusted as final; the CEN base value's less severe λlim = 13.6 doesn't change the conclusion either.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze RCC Column module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The free trial covers a curated set of flagship modules including this one. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does a column that passes its strength checks still fail overall?

Slenderness isn't a strength check at all — it's a screening test for whether second-order (P-Δ) effects are large enough that the straightforward N–M interaction, run against the applied first-order moment alone, would understate the real demand. A slender column needs its moment magnified before the interaction check means anything.

What's the practical fix for a slender column?

Either add the second-order moment explicitly (nominal-curvature method, EN 1992-1-1 Cl 5.8.8) and re-run the interaction check with the magnified MEd, or brace the column to shorten its effective length and bring λ back under the limit.

Final Thoughts

A column's slenderness check is the one that actually gates whether the rest of the calculation can be trusted — running the interaction check first and skipping slenderness is a truly common way to miss that a column needs a second-order analysis.