Eurocode 3's Ayrton-Perry buckling curve applies identically to a truss chord and diagonal — only the buckling curve selection and each member's own slenderness differ, and a truly mixed truss (rolled chords, cold-formed diagonals) would need two different imperfection factors, not the single shared selection a simpler model might assume.

Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Span 16 m, depth 1.6 m, 8 panels
  • Panel point load (service) 20 kN
  • Chord: area 2500 mm², i = 35 mm, buckling length 2 m
  • Diagonal: area 2200 mm², i = 28 mm, buckling length 2.5 m
  • Buckling curve c; material S235, fy = 235 MPa

Working Through It

With Eurocode 3's variable-action factor of 1.5 (not AISC's 1.6), the equivalent factored UDL is 15 kN/m, giving MEd = 480 kN·m and VEd = 120 kN. Chord force = 480/1.6 = 300 kN; diagonal force = 120/sin(38.66°) ≈ 192.1 kN.

Bottom chord tension checks against Npl,Rd = Agfy/γM0 ≈ 587.5 kN (utilisation 0.511). Both the top chord and diagonal use the identical Ayrton-Perry buckling curve at buckling class c (αimp = 0.49) — giving χ = 0.780 for the chord and χ = 0.569 for the diagonal.

What Governs, and Why

Top chord and diagonal compression run almost identically at utilisation 0.654 and 0.653 despite very different slenderness ratios (57.1 vs 89.3) — the diagonal's smaller area and larger imperfection-driven reduction happen to roughly offset its lighter force, a coincidence of this particular geometry rather than a general rule. Both comfortably clear the tension chord's 0.511.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Steel Truss module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Steel Truss and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why would a mixed-material truss need two different buckling curves?

Table 6.2's buckling curve assignment depends on section shape, axis, and fabrication method — a rolled I-section chord and a cold-formed hollow-section diagonal have genuinely different residual-stress patterns, so they'd be assigned different curves (and different αimp values) even within the same truss, which this simplified single-selection model doesn't capture.

Why is the panel-point load factored at 1.5, not something else?

This book treats the panel-point load as dead-load-dominated, using EN 1990 Expression 6.10's permanent-action factor — a really live-load-dominated truss loading would need the corresponding variable-action factor applied instead.

Final Thoughts

The near-coincidental tie between top chord and diagonal utilisation here is a reminder that slenderness alone doesn't predict which member governs — the interplay between force, area and the imperfection factor decides it.