IS 800's Cl 7.1.2 buckling curve needs one ingredient AISC 360's single formula doesn't: a buckling class (a–d) that sets the imperfection factor α — and the exact same physical section can truly carry less margin under IS 800 than the identical geometry checked against AISC 360, purely from that one code-specific difference.

Every check above runs automatically inside the Structyze Compression/Tension Member module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Section 250 × 250 × 12 × 8 mm (I-shape/channel)
  • Effective length 3.5 m
  • Buckling class c (rolled H-section, minor axis)
  • Axial load: dead 200 kN, live 150 kN
  • Material Fe410 (E250), fy = 250 MPa

Working Through It

Section classification (Table 2) finds both the flange and web semi-compact — not slender, so Cl 7.1.2 applies. Slenderness KL/ry = 3500/63.28 ≈ 55.32, well under the practical 180 limit.

Including self-weight, the factored axial load Pu = 1.5(200+150+2.105) ≈ 528.2 kN. The Euler elastic buckling stress fcc = π²E/(KL/ry)² ≈ 645.0 MPa gives λ̄ = √(250/645.0) ≈ 0.623. At buckling class c (α = 0.49): φ = 0.797, χ = 0.772, design compressive stress fcd = 0.772(250)/1.1 ≈ 175.4 MPa, giving Pd ≈ 1370 kN.

What Governs, and Why

Compression buckling governs at utilisation 0.386, comfortably ahead of the slenderness margin (0.307). Worth noting squarely against the identical geometry checked under AISC 360 elsewhere in this series (utilisation 0.249 there): IS 800's class-c curve combined with the γm0 = 1.10 partial safety factor gives a visibly lower design stress than AISC's own column curve at the same KL/r — a genuine, code-specific difference, not an inconsistency between the two calculations.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Compression/Tension Member module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Compression/Tension Member and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

What decides which buckling class a section falls into?

IS 800 Table 10 assigns buckling class by section shape, fabrication method, and the axis being checked — the same rolled I-section is typically class b about its major axis but class c about its minor (weaker) axis, since the minor axis has a different residual-stress pattern relative to its stiffness.

Why compare the same section across IS 800 and AISC 360?

Because the underlying physics (Euler buckling, an imperfection-sensitive curve) is nearly identical between the two codes — comparing the same geometry side by side isolates how much of the difference in final capacity comes from each code's own partial factors and curve calibration, rather than from any modelling choice.

Final Thoughts

A steel column's buckling class selection is a small input that changes the final capacity meaningfully — useful to double-checking by hand rather than defaulting to whichever class feels familiar from a different code.

One thought on “How to Design a Steel Column (Axial Member) to IS 800 (Step by Step, With Free Software)”

Leave a Reply

Your email address will not be published. Required fields are marked *