A silo is a deep bin, tall enough that wall friction mobilises and arches part of the stored material's weight onto the walls — Janssen's equation captures this closely, and it converges to the same linear (Rankine-type) pressure a shallow bunker would use as depth approaches zero, confirming the two theories genuinely agree at shallow depth.
Every check above runs automatically inside the Structyze RCC Silo module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
The Example We'll Use
- Internal diameter 6 m, height of fill 15 m
- Wall thickness 200 mm, cover 40 mm
- Stored material: grain, γ = 8 kN/m³, φ = 25°, wall friction δ = 20°
- Materials M25, Fe415
Working Through It
Janssen's pressure ratio K = (1−sin25°)/(1+sin25°) ≈ 0.406, and the hydraulic radius Rh = D/4 = 1.5 m. At the base of the fill (z = 15 m), the exponent μKH/Rh = 1.478 gives pv(15) ≈ 62.7 kN/m² and horizontal pressure ph(15) = K·pv(15) ≈ 25.4 kN/m².
That horizontal pressure produces hoop tension in the wall specifically as in a circular tank: T = ph(H)·R ≈ 76.3 kN/m, Tu = 114.5 kN/m, requiring Ast ≈ 317 mm²/m — this time above the Cl 26.5.2.1 minimum of 240 mm²/m, so calculated strength governs the hoop steel here, unlike the shallower bunker case where minimum steel typically wins.
A separate wall vertical-stress check accounts for the accumulated friction drag as material slides against the wall over the full 15 m height, plus the wall's own self-weight — giving a net vertical stress of 1.19 MPa against a 6.25 MPa limit (0.25fck), passing with wide margin.
What Governs, and Why
Hoop tension governs the wall design at utilisation 0.40, with the calculated demand itself exceeding the code minimum — unlike a shallower bunker, a deep silo's Janssen pressure is large enough at depth that strength, not the code floor, truly sizes the hoop steel. The hopper and floor support carrying the discharge outlet need their own separate tension design.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze RCC Silo module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.
For RCC Silo and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
How is Janssen's theory different from a simple linear (Rankine) pressure?
Rankine pressure assumes the full weight of material above a given depth bears straight down through that point, growing linearly with depth forever; Janssen's theory instead accounts for wall friction carrying part of that weight into the walls, so pressure approaches an asymptotic limit at depth rather than increasing without bound — the two theories converge at shallow depth, where wall friction hasn't yet had height to mobilise.
Why is abrasion a bigger concern here than in a water tank?
Moving granular material sliding against the interior face during filling and discharge is considerably more abrasive than static liquid contact — a denser cover concrete or a sacrificial liner on the material-contact face is common practice specifically for this reason.
Final Thoughts
Janssen's equation is the one really silo-specific piece of theory in this whole series — getting the hydraulic radius and wall-friction angle right by hand is easy to fumble on a first attempt.