An in-ground swimming pool is structurally just a buried rectangular tank — it shares the identical two-case load model (full pool/no backfill, and empty pool/full backfill) with an underground tank, and at typical domestic water depths, minimum steel governs both walls rather than the calculated bending moment.

Every check above runs automatically inside the Structyze Swimming Pool module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Internal 10 × 5 m, water depth 1.8 m
  • Wall 10 in, base 12 in
  • Backfill γ = 115 pcf, φ = 30°; water table at base
  • Allowable bearing 2.0 ksf
  • Interior/exterior bars #4 at 6 in

Working Through It

Case 1 (pool full): hydrostatic pressure pmax = 62.4(6) ≈ 374 psf gives Mu = 3.14 kip·ft per foot — but the calculated As comes out below the ACI minimum of 0.0018bt = 0.22 in², so minimum steel governs rather than the bending calculation.

Case 2 (pool empty, full backfill): active earth pressure gives Mu = 2.81 kip·ft per foot — again below minimum steel.

Both one-way shear (2.5 kip against a 9.4 kip capacity) and bearing (0.75 ksf against 2.0 ksf allowable) carry wide margin, and with the water table sitting at the base, flotation is automatically satisfied.

What Governs, and Why

Both flexure checks land at the identical utilisation 0.56, since minimum steel — not either calculated moment. Governs both faces at this shallow 6 ft water depth. This is typical for a domestic pool; a diving well, or a pool built into a slope, would change the earth-pressure case and the flotation check enough to need re-running with the actual site values.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze Swimming Pool module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For Swimming Pool and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why is this the same underlying model as an underground tank?

The load paths are identical — a buried rectangular box resisting internal hydrostatic pressure one way and external earth pressure the other — only the default dimensions and the shallower water depth differ between the two modules.

What would change for a pool with a deep end or built into a slope?

A varying depth profile changes both the governing water-pressure case and, if the site slopes, introduces an asymmetric backfill condition that the flat two-case model here doesn't closely capture — and flotation risk rises meaningfully if the water table can be higher than the pool floor when the pool is drained for maintenance.

Final Thoughts