A cold-formed steel tube column has to clear two genuinely independent buckling checks — global flexural buckling of the whole member, and Direct Strength Method local buckling of its thin walls. And AISI S100's column provision applies the local-buckling reduction on top of the already-reduced global capacity, not against the full yield load.

Every check above runs automatically inside the Structyze CFS Stud / Column module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

The Example We'll Use

  • Section 100 × 100 × 2.0 mm (box/tube)
  • Unbraced length 2500 mm
  • Factored axial load 100 kN
  • Material ASTM A1003 Grade 50, Fy = 345 MPa

Working Through It

Gross section properties come out to Ag = 784 mm² and r = 40.0 mm, giving KL/r = 62.5. Global (Euler-type) buckling: Fe = π²E/(KL/r)² ≈ 505.8 MPa, and since Fy/Fe = 0.682 ≤ 2.25, the inelastic buckling formula applies: Pne = 0.6580.682(784)(345) ≈ 203.3 kN.

Here's the DSM-specific step: local buckling isn't checked against the yield load squarely. Instead, λl = √(Pne/Pcrl) uses the already-reduced global capacity Pne as its reference. With Pcrl ≈ 246.1 kN from the wall's local elastic buckling stress, λl = 0.909, past the DSM transition point of 0.776, giving Pnl ≈ 183.9 kN.

The governing capacity Pn = min(203.3, 183.9) = 183.9 kN — local buckling wins out over pure global buckling, and φPn = 0.85(183.9) ≈ 156.3 kN against the 100 kN demand.

What Governs, and Why

Local buckling governs over pure global buckling (183.9 kN vs 203.3 kN) — a real, expected outcome for this thin-walled section, not a rounding artifact. The wall's own plate slenderness (w/t = 48) is high enough that local buckling knocks nearly 10% off the already-reduced global capacity, giving a final utilisation of 0.640.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze CFS Stud / Column module — this particular module is part of the full desktop catalogue rather than the free browser trial, since the trial only carries a curated flagship set. You can still try the free trial modules right now to see the same calculation style in action on RCC Beam, Column, Slab and a handful of others.

For CFS Stud / Column and the rest of the full catalogue — 80+ components across RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

Why does local buckling use Pne as its reference, not the yield load?

AISI S100's own column provision is written this way deliberately — a slender column that has already lost capacity to global buckling shouldn't get a separate, independent local-buckling penalty computed against the full yield load; layering the reduction on top of Pne reflects how the two failure modes actually interact.

What buckling mode isn't checked here?

Distortional buckling — a third failure mode specific to open (lipped-C) cold-formed sections — isn't checked in this closed box/tube example. A doubly-symmetric closed section like this one is also not subject to the flexural-torsional buckling mode that an open C-section would need checked separately.

Final Thoughts

The DSM local-buckling-on-top-of-global-buckling logic is the single most code-specific idea in cold-formed steel design, and it's easy to apply backwards (checking local buckling against the yield load instead of Pne) without realizing the mistake.