AS 3600 designs a one-way slab as an ordinary 1 m-wide beam strip and a two-way flat plate through the same column-strip/middle-strip static-moment distribution — but the deemed-to-comply deflection ratio for a one-way slab is tighter than it first looks, and a flat plate can pass Australian punching shear while the identical panel would flag under Eurocode 2.
Every check above runs automatically inside the Structyze RCC Slab module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.
The Example We'll Use
- One-way slab: clear span 4 m continuous, thickness 150 mm, cover 20 mm
- Flat plate: 6 × 6 m panel, square column 400 mm, slab 250 mm
- Superimposed dead 1.5 kN/m², imposed 3.0 kN/m² (both cases)
- Materials N32 concrete, 500N steel
Working Through It
For the one-way slab, the governing design load w* = max(1.35G, 1.2G+1.5Q) = 10.6 kN/m² gives a moment M* = w*L²/10 ≈ 17.0 kN·m/m — comfortably covered by N12 bars at 150 mm (utilisation 0.45). But the actual span/depth ratio of 32.3 exceeds the deemed-to-comply limit of roughly 28–30 for a continuous slab at this load, flagging that an explicit deflection calculation (or a thicker slab) is genuinely needed.
For the flat plate, the static moment Mo = 13.5(6)(5.6)²/8 ≈ 317 kN·m splits to a column-strip negative moment of 51.6 kN·m/m, requiring N16 bars at 200 mm (utilisation 0.58).
Punching shear at the column, u = 4(400+214) = 2456 mm, gives φVuo = 758 kN against a moment-amplified demand of about 577 kN — utilisation 0.76, passing with real margin.
What Governs, and Why
The one-way slab's deflection check is the only genuine failure here (ratio 1.15 against the limit) — everything else passes, including, notably, the flat plate's punching shear check at utilisation 0.76. That's worth contrasting directly with Eurocode 2: the identical flat-plate panel geometry flags on both minimum thickness and punching under EN 1992, because AS 3600's punching coefficient (0.34√f′c) is measurably more generous than the Eurocode 2 equivalent.
Where Structyze Takes Over
Every check above runs automatically inside the Structyze RCC Slab module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.
The free trial covers a curated set of flagship modules including this one. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.
Quick FAQ
Why would the same panel pass under AS 3600 but flag under Eurocode 2?
The two codes' punching shear provisions use different empirical coefficients calibrated against different test data — AS 3600's fcv = 0.34√f′c term is simply less conservative than the Eurocode 2 vRd,c relation for this particular geometry, a genuine code difference rather than a modelling error.
What's the fix for the one-way slab's deflection flag?
Either run an explicit AS 3600 Cl 8.5.3 deflection calculation (which can still pass, since deemed-to-comply ratios are inherently conservative), or simply thicken the slab — roughly 175 mm would likely clear the ratio comfortably.
Final Thoughts