Designing an RCC beam to Canada's CSA A23.3 follows a truly different shear model to IS 456 or ACI 318 — a fixed 35° strut angle in the simplified method, and a shear depth dv that isn't simply the effective depth but the larger of two separate definitions.

Every check above runs automatically inside the Structyze RCC Beam module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The Example We'll Use

  • Clear span 5 m, continuous both ends
  • b × h = 300 × 500 mm, cover 40 mm
  • Superimposed dead 5 kN/m, live 8 kN/m
  • Concrete f′c = 25 MPa, steel 400W (fy = 400 MPa)
  • Main bars 4–20M; stirrups 10M (2-leg) at 250 mm

Working Through It

Effective depth d = 438 mm, but the shear depth dv = max(0.9d, 0.72h) = max(394, 360) = 394 mm — a CSA-specific definition that feeds directly into the shear check later.

Factored load wf = 1.25(8.6) + 1.5(8) = 22.75 kN/m (checked against the alternative 1.4D load case, which doesn't govern). The support moment Mf− = 47.4 kN·m governs over the span moment.

Working the bending design through α1 = 0.8125 and β1 = 0.9075 (both f′c-dependent per CSA A23.3) gives a required As around 330 mm² — but the Cl 10.5.1.2 minimum steel requirement, 0.2√f′c·bth/fy ≈ 375 mm², is actually higher and governs instead.

Shear demand Vf = 46.9 kN at dv from the support face stays below the concrete-alone capacity Vc = φcλβ√f′cbwdv ≈ 69.2 kN (using β = 0.18, the simplified-method default with minimum stirrups) — so only minimum stirrups are required, not a calculated Vs.

What Governs, and Why

Stirrup spacing runs tightest at utilisation 0.91 against the 0.7dv limit, with shear itself close behind at 0.68. Minimum steel, not calculated bending demand, governs the main bar count — and relative to the equivalent Eurocode 2 design, CSA's lower 400 MPa yield steel needs roughly 25% more bar area for the same moment.

Where Structyze Takes Over

Every check above runs automatically inside the Structyze RCC Beam module, free to try online — change any input and every downstream number recalculates instantly, with the governing code clause shown next to each result.

The free trial covers a curated set of flagship modules including this one. For the full catalogue — RCC, Steel, Composite, Timber, Masonry and more, across 20+ design codes — buy the full Structyze desktop app or see everything it does on the Software page.

Quick FAQ

What is dv and why does CSA define it separately from d?

dv is the effective shear depth used specifically in CSA's shear provisions — taken as the larger of 0.9d and 0.72h to avoid an unrealistically small shear depth on a lightly-reinforced or unusually proportioned section.

Why 35° for the strut angle?

CSA A23.3's simplified method fixes the strut inclination at 35° rather than solving for the code's full variable-angle truss model — a conservative, code-permitted shortcut that avoids an iterative calculation for an ordinary beam.

Final Thoughts

CSA A23.3's shear-depth definition and fixed 35° strut angle are two small but very code-specific details that are easy to import incorrectly from an ACI 318 or Eurocode 2 habit.